Owner's manual
Problem
LED Flashing
One Time
Flash pattern begins
immediately, fan motor
does not run. Heater
does not light.
Is flapper or
air-proving switch arm
binding on housing? Is
there an obstruction in
heater outlet?
Is air-
proving switch
shorted? (Perform
continuity check on air-
proving switch.)
Yes
No
Repair and/or remove obstructions.
Yes
Replace air-proving switch.
Long Flash
Two seconds
on, two
seconds off
repetitively
for 15 minutes.
Heater has attempted two ignition trials. Heater is in a 15 minute wait period before attempting its third
(final) trial for ignition. If ignition is not achieved after the third trial, the heater will lock out and the
ignition control module will present the three time flash pattern. Either recycle the heater or wait for
heater to attempt third ignition trial.
21