Install Manual

Preliminary
SKY899
Installation Manual
B-4
Rev. A
Revision & Change Number of DO-160: DO-160C
CONDITION
SECTION/
PARAGRAPH
TEST DESCRIPTION
Temperature and Altitude 4.0 Tested to Category F1-
Operating Low Temperature 4.5.1
-20° Celsius
Operating High Temperature 4.5.3
+55° Celsius
Short-Time Operating High Temp. 4.5.2 +70° Celsius
Loss of Cooling 4.5.4 -Not Applicable-
Ground Survival Low Temp. 4.5.1 -55° Celsius
Ground Survival High Temp. 4.5.2 +85° Celsius
Altitude 4.6.1 55,000 Feet MSL
Temperature Variation 5.0 Tested to Category C
Humidity 6.0 Tested to Category A
Operational Shock and Crash Safety 7.0
Operational Shock 7.2
6 g's Peak
Crash Safety 7.3
15 g's all axes
Vibration 8.0
Tested to Categories [NBM] Instrument
Panel Mount Without Vibration Isolators
Explosion Proofness 9.0 Category X - No test required
Waterproofness 10.0 Category X - No test required
Fluids Susceptibility 11.0 Category X - No test required
Sand and Dust 12.0 Category X - No test required
Fungus Resistance 13.0 Category X - No test required
Salt Spray 14.0 Category X - No test required
Magnetic Effect 15.0 Tested to Class Z
Power Input 16.0 Category X - No test required
Voltage Spike 17.0 Category X - No test required
Audio Frequency Susceptibility 18.0 Category X - No test required
Induced Signal Susceptibility 19.0 Tested to Category Z
Radio Frequency Susceptibility 20.0 Tested to Category U
Radio Frequency Emission 21.0 Tested to Category A
Lightning Induced Transient
Susceptibility
22.0 Category X - No test required
Lightning Direct Effects 23.0 Category X - No test required
Icing 24.0 Category X - No test required
Other Tests X-Ray Radiation
Other Tests U.V. Radiation
Other Tests Thermal Shock