Install Manual Part 3

SKY497
Installation Manual
4-7
Rev. C
NOTES
1. Saved configuration data is read at power-up and compared with
configuration jumpers. If the saved configuration data has never been
saved (e.g., new installations) an ERROR 30 Check Configuration will
occur when the box comes out of standby. If the saved configuration data
does not match the current jumper(s) an error 30 will occur at power-up.
The conflicting jumper(s) will be highlighted on configuration screen(s).
(See figure 4-8.)
2. Configuration pages 1, 3 and 4 contain configuration jumper data. On
each page verify jumpers are correct and press SAVE to write the new
configuration into system memory. When done the SAVE button
disappears. Repeat this step for each page. Save command can be used if
using a terminal device.
Figure 4-8. Configuration - Page 1
Page 1 of 4 (see figure 4-8) displays:
Heading Input Source (Hdg.: XYZ, STEP, 429, or NONE)
Configuration Jumpers P1-69 & P1-70 (OPEN or GND)
P1-69 P1-70
None OPEN OPEN
Synchro XYZ OPEN GND
Stepper GND OPEN
ARINC 429 Bus GND GND
Heading Flag Sense (HIGH or LOW)
Configuration Jumper P1-68 (OPEN or GND)
P1-68
OPEN If LOW level input on HDG_FLG+ (P1-53) indicates
valid heading or no valid heading input is available.
GND If HIGH level input on HDG_FLG+ (P1-53) indicates
valid heading.
RS422 Interface (DR/Alt. 422: DR or 422)
Configuration Jumper P1-67 (OPEN or GND)
P1-67
Data Recorder OPEN
Alternate* GND
*Future Option