Installation Manual
4-5
Rev. C
The System Log displays the results in the following format:
### HHHHH:MM
where:
### = Error code.
HHHHH:MM = Run-time (in hours and minutes) at which error occurred.
The total elapsed run-time is displayed in the upper middle portion of the screen (System Time
HHHHH:MM).
A textual description of the highlighted error entry is displayed in the bottom portion of the screen.
If the System Log is empty, the following message is displayed:
NO FAULTS DETECTED
If, due to a failure of non-volatile memory, the System Log cannot be displayed, the following message is
displayed:
DATA NOT AVAILABLE
The buttons perform the following operations:
• EXIT - causes the system to return the Service Menu.
• NEXT - steps to the next entry.
• PREV - steps to the previous entry.
• Soft-key (4) is not used.
4.4.3 System Data
System Data screens (see figures 4-6 through 4-16) contain a record of setup information (software
identification and jumper configuration) and real-time sensor data. If you have problems with the SKY497,
verify the configuration screens match the wiring diagrams (see figures 2-2 and 2-3) and have this
information available when contacting BFGoodrich Avionics Systems Field Service Engineering. The field
service engineer must have adequate information to diagnose a problem. System Data screens are accessed
by selecting that option from the Service Menu (i.e., press SELECT with System Data high-lighted).
The System Data screen provides the following choices:
• Software Version
• Configuration
• Data Monitor
Figure 4-6. System Data