Data Sheet
Safety Warnings :
Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely
for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure
to operate the instrument on a correct power supply and voltage rating marked on each instrument.
2000 2001 2012R
DC V
340.0mV/3.400/34.00/340.0/600V
(
Input impedance: approx. 10M
Ω)
±
1.5%rdg
±
4dgt
600.0mV/6.000/60.00/600.0V
(
Input impedance: approx. 10M
Ω)
±
1.0%rdg
±
3dgt
AC V
3.400/34.00/340.0/600V
(
Input impedance: approx.10M
Ω)
±
1.5%rdg
±
5dgt
(
50
∼
400Hz
)
6.000/60.00/600.0V
(
Input impedance: approx.10M
Ω)
±
1.5%rdg
±
5dgt
(
45
∼
400Hz
)
DC A
60.0A
±
2%rdg
±
5dgt
100.0A
±
2%rdg
±
5dgt
60.00/120.0A
±
2.0%rdg
±
8dgt
(
60A
)
±
2.0%rdg
±
5dgt
(
120A
)
AC A
60.0A
±
2%rdg
±
5dgt
(
50/60Hz
)
100.0A
±
2%rdg
±
5dgt
(
50/60Hz
)
60.00/120.0A
±
2.0%rdg
±
5dgt
(
45
∼
65Hz
)
Ω
340.0
Ω
/3.400/34.00/340.0k
Ω
/3.400/34.00M
Ω
±
1%rdg
±
3dgt
(
0~340k
Ω)
±
5%rdg
±
5dgt
(
3.400M
Ω)
±
15%rdg
±
5dgt
(
34.00M
Ω)
600.0
Ω
/6.000/60.00/600.0k
Ω
/6.000/60.00M
Ω
±
1.0%rdg
±
5dgt
(
600
Ω
/6/60/600k
Ω)
±
2.0%rdg
±
5dgt
(
6M
Ω)
±
3.0%rdg
±
5dgt
(
60M
Ω)
Continuity buzzer Buzzer sounds below 30
±
10
Ω
Buzzer sounds below 35
±
25
Ω
Diode test
−
2V
±
3.0%rdg
±
5dgt
Open-loop voltage: approx. 2.7V
Capacitance
−
400.0nF/4.000/40.00
μ
F
±
2.5%rdg
±
10dgt
Frequency
(
AC A
)
3.400/10.00kHz
±
0.1%rdg
±
1dgt
(
AC V
)
3.400/34.00/300.0kHz
±
0.1%rdg
±
1dgt
(
AC A
)
100/1000Hz/10kHz
±
0.2%rdg
±
2dgt
(
100Hz
)
±
0.1%rdg
±
1dgt
(
1000Hz/10kHz
)
(
AC V
)
100/1000Hz/10/100/300.0kHz
±
0.2%rdg
±
2dgt
(
100Hz
)
±
0.1%rdg
±
1dgt
(
1000Hz/10/100/300.0kHz
)
(
Input sensitivity)
Current: more than 2A
Voltage: more than 2V
[∼
10kHz
]
/more than 20V
[
10k
∼
300kHz
]
(
Input sensitivity
Current: more than 15A
Voltage: more than 30V
)
(
Input sensitivity
Current: more than 25A
Voltage: more than 30V
)
Conductor size
φ
6mm max.
φ
10mm max.
φ
12mm max.
Withstand voltage 3700V AC for 1 minute 3540V AC for 5 seconds
Applicable
standards
IEC 61010-1 CAT.
Ⅲ
300V, CAT.
Ⅱ
600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326
IEC 61010-1 CAT.
Ⅲ
300V, CAT.
Ⅱ
600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326
Power source
R03
(
1.5V
)×
2
*Continuous measuring time: approx. 45hours
(
Auto power save: approx. 10 minutes
)
R03
(
1.5V
)×
2
*Continuous measuring time: DCV: approx. 150hours,
ACA: approx. 25hours
(
Auto power save: approx. 15 minutes
)
Dimensions 128
(
L
)×
87
(
W
)×
24
(
D
)
mm 128
(
L
)×
91
(
W
)×
27
(
D
)
mm 128
(
L
)×
92
(
W
)×
27
(
D
)
mm
Weight
210g approx.
(
including batteries
)
220g approx.
(
including batteries
)
220g approx.
(
including batteries
)
Accessories R03
(
1.5V
)×
2
Instruction manual
Optional 9107
(
Carrying case
[
Soft
])
φ
6
φ
10
φ
12
MAX
AC/DC 60A
MAX
AC/DC 100A
MAX
AC/DC 120A
●
2000/2001/2012R Specifications