Datasheet

www.kyland.com
91
Alarm Contact
3-pin 5.08mm-spacing plug-in terminal block,250VAC/220VDC Max,
2A Max
LED
LEDs on Front Panel
Running LED: Run
Alarm LED: Alarm (12/24/48VDC model only)
Power LED: PWR1,PWR2
Ring LED: Ring
Interface LED: Link/ACT, Speed (RJ45 port); Link/ACT(Fiber port)
Button
Reset: Reboot and restore default configuration
Power Requirement
Power Input
100-240VAC, 50/60Hz; 110-220VDC(85-264VAC/77-300VDC)
24-48VDC(18-72VDC)
12-24VDC(9-36VDC)
Power Terminal
5-pin 5.08mm-spacing plug-in terminal block
Power Consumption <8.1W
Overload Protection Support
Reverse Protection Support
Redundancy Protection Support (12/24/48VDC)
Physical Characteristics
Housing Metal
Cooling Natural convection, fanless
Protection Class IP40
Dimension
53.6mm×135mm×106.5mm(W×H×D) (12/24/48VDC)
66mm×135mm×106.5mm (W×H×D) (220VAC/DC)
4
Weight 0.76Kg
Mounting DIN-Rail or Panel Mounting
Environmental Limits
Operating Temperature
-40°C to +85°C(12/24/48VDC)
-40°C to +75°C(220VAC/DC)
Storage Temperature -40°C to +85°C
Ambient Relative Humidity 5-95% (non-condensing)
Warranty
MTBF 385,000 hrs
Warranty 5 years
Approvals
UL508, Class I Div 2: Models with L2:24-48VDC
CE(EMC), FCC: Models with L2:24-48VDC and L5:12-24VDC
UL certified max operating temperature is 75°C.
Industry Standard
EMI
FCC CFR47 Part 15,EN55022/CISPR22,Class A
EMS
IEC61000-4-2(ESD) ±8kV(contact),±15kV(air)
IEC61000-4-3(RS) 10V/m(80MHz–2GHz)
IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV
IEC61000-4-5(Surge) Power Port: ±2kV/DM, ±4kV/CM; Data Port:±2kV
IEC61000-4-6(CS) 10V (150kHz–80MHz)
Machinery
IEC60068-2-6 (Vibration)
IEC60068-2-27 (Shock)
IEC60068-2-32 (Free Fall)
Industrial Ethernet Solutions
>

Mechanical Drawing
Din Rail Mounting (Low voltage version)
Din Rail Mounting (High voltage version)
Panel Mounting (Low voltage version)
6
35
66 107.5
135
66