User's Guide
K60x User Guide
9 LED Indicator Codes
K60x is equipped with a single double color (red and green) LED indicator. The following are
the LED indication modes. The sequences indicate the LED state during each 150ms time
slot
● during boot up: solid red
● normal operation:
o no wireless link: repeat the sequence: green, off, off, green, off, off ...
o established wireless link:
▪ Hub: solid green
▪ Remote: signal quality from 1 blink for weakest to 5 blinks for the
strongest between pauses. Example: for link quality of 3 the repeat
sequence is: pause green green green
● error condition:
o repeat the sequence: red, off, red, off, red, off, off, off
● identify the unit
o repeat the sequence: red, green
● signal for reset to factory defaults:
o repeat the sequence: green, red, green, red, green, red, off, off
● restore factory defaults is in progress:
o repeat the sequence: red, off, red, off, off, off, green, off, green, off, off, off
10 Using the K60x Web User Interface (UI)
10.1 Requirements
The K60x embedded WebUI allows for direct configuration of both Hub and Remote units.
It is a standard web application that runs directly on the K60x unit and is accessible
through the default port for HTTPS (443) at URL https://<Host name of the unit>. Your
browser will display a warning stating that the connection is not secure. You may ignore the
warning and proceed connecting to the unit. To avoid the warning, go to the Kwikbit
support website, download the Kwikbit security certificate, and install it on your browser.
The recommended browsers for the K60x WebUI are:
● Google Chrome
● Safari
Operating System (OS) support for K60x WebUI:
● Windows
Kwikbit K60x User Guide - 19 -