User's Guide
K60i User Guide
Modulation and Coding Rate (MCS) which varies according to link and signal conditions. The
following table details Ethernet uplink and downlink combined throughput for a K60i link.
Table 8: Throughput Performance for Cyclic Prefix of 1/8
MCS Index
Modulation
NCBPS
Repetitions
Code Rate
Data Rate
(Mbit/s)
1
π/2 BPSK
1
2
1/2
310
2
π/2 BPSK
1
1
1/2
620
3
π/2 BPSK
1
1
5/8
775
4
π/2 BPSK
1
1
3/4
930
5
π/2 BPSK
1
1
13/16
1007
6
π/2 QPSK
2
1
1/2
1240
7
π/2 QPSK
2
1
5/8
1550
8
π/2 QPSK
2
1
3/4
1860
6 Element and Network Management
The K60i system supports the following network management interfaces:
● K60i Web Interface (WebUI). Accessible via HTTP(S), the K60i WebUI provides an
interactive visual toolset that allows an operator to modify the full configuration of
the K60i system as well as view state, fault, and performance indicator.
● The Edge Controller WebUI application provides complete access to configuration,
state, performance and fault information for all K60i units in a network system.
The WebUI network management interface on the K60i system is accessible via HTTP(S).
Connect to the K60i system with your browser utilizing one of the following methods:
● Local Name: Connect a K60i transceiver unit directly to your computer by plugging
an Ethernet cable into any of the K60i’s three RJ45 connectors. In the URL field on
your computer’s browser type https://KB-XX-XX-XX.local where KB-XX-XX-XX is
the Host name of the unit that appears on the sticker on the back of the unit. For
Kwikbit K60i User Guide
Confidential & Proprietary - 15 -