User's Guide
● K60c Web Interface (WebUI). Accessible via HTTPS, the K60c WebUI provides an
interactive visual toolset that allows an operator to modify the full configuration of
the K60c system as well as view state, fault, and performance indicator.
● K60c Command Line Interface (CLI) provides a set of commands that allows the
operator to manage, maintain and troubleshoot the system.
● The Edge Controller WebUI application provides complete access to configuration,
state, performance and fault information for all K60c units in a network system.
The WebUI network management interface on the K60c system is accessible via HTTPS.
Power the unit with a PoE power source. Connect to the K60c system with your browser
utilizing one of the following methods:
● Local Name: Connect a K60c transceiver unit directly to your computer by plugging
an Ethernet cable into the RJ45 connector. In the URL field on your computer’s
browser type https://KB-XX-XX-XX.local where KB-XX-XX-XX is the Host name of
the unit that appears on the label on the side of the unit. For example, if the unit
Host name is KB-C5-6B-78, then the URL address of the unit is
https://KB-C5-6B-78.local. Your browser will display a warning stating that the
connection is not secure. You may ignore the warning and proceed connecting to
the unit. To avoid the warning, please go to the Kwikbit support website, download
the Kwikbit security certificate, and install it on your browser.
● Management IP Address: Connect using the IPv4 IP address. The factory-assigned
IP address appears on a temporary label on the unit. Be sure to use https:// rather
than http.
The Command Line Interface network interface on the K60c system is accessible via Secure
Shell (SSH). Power the unit with a PoE power source. Connect to the K60c system with your
terminal application utilizing one of the following methods:
● Local Name: Connect a K60c transceiver unit directly to your computer by plugging
an Ethernet cable into the RJ45 connectors. In a terminal application window on
your Linux, Unix or MAC computer type ssh kwikbit@KB-XX-XX-XX.local where
KB-XX-XX-XX is the Host name of the unit that appears on the label on the side of
the unit. For example, if the unit Host name is KB-C5-6B-78, then the command line
is ssh kwikbit@KB-C5-6B-78.local. For the password prompt enter kwikbit.
● Management IP Address: Connect using the IPv4 IP address. The factory-assigned
IP address appears on a temporary label on the unit.
The optional Kwikbit Edge Controller’s management application automatically discovers all
connected K60c devices on the network and establishes a secure connection to each one
utilizing a security certificate provided by Kwikbit and customized by the customer. For
Kwikbit K60c User Guide - 15 -
K60c User Guide