User's Guide

K60 User Guide
non-technical staff as precise mechanical alignment, as required by previous generation 60
GHz systems, is not required.
The K60 system is designed for use in multiple applications including gigabit access, IoT
backhaul (sensors, security cameras, etc.), optical fiber extension, and corporate and
enterprise data services by providing 1 Gbps of symmetric throughput.
The K60 system operates in unlicensed Time Division Multiplexing (TDD) band 57.05 – 64.00
GHz in both Point-to-Point (PtP) and Point-to-Multipoint (PtMP) configurations. Some of the
main product characteristics are shown in Table 1.
Table 1: Main K60 Characteristics
Duplex Mode
Time Division Multiplexing (TDD)
Physical Layer / Antenna
System
128 patch beamforming antenna
Operation Configuration
PtP and PtMP
Capacity
1.86 Gbps goodput aggregate
Symmetry
Dynamic downlink (DL) and uplink
(UP) based on offered load
Frequency of Operation
57.05 – 64.00 GHz
Channel Bandwidth
2.16 GHz
Network Interface
2 x 2.5 gigabit Ethernet
1x 1 gigabit Ethernet
Form Factor
7.75 x 4 x 2.5” with integrated
antenna
The K60 system consists of the following components:
Hub Unit: control communication to one or more Remote Units
Remote Unit: scan for available Hub Units and connect to the Hub configured or
assigned via the Edge Controller
Edge Controller: Optional appliance computer that provides WebUI tools for
deployment planning, commissioning, network configuration, management,
Kwikbit K60 User Guide - 7 -