TracVision G8 Owner's Manual
7. Reconnect the cables that you removed in Step 4. Be
sure to reconnect all cables in their proper positions.
Figure 5-6 shows the proper connector assignments.
Figure 5-6
PCB Module Connectors
8. Apply power to the antenna unit.
9. Using the PC connected to the maintenance port, type
HALT then press Enter.
10. Type
DEBUGON then press Enter.
11. Type
=TVG8SS then press Enter.
12. Type
=SERNUM,<serial number>, where <serial
number> = the serial number you recorded in Step 2.
Then press Enter.
13. Type
ZAP then press Enter to restart/reinitialize the
system.
14. Calibrate the antenna gyros as explained in “Calibrating
the Gyros” on page 105.
15. Reinstall your selected satellites as explained in Section 2.7,
“Installing Satellites Using the MCU,” on page 42.
54-0198
100
TracVision G8 Owner’s Manual - Guide to Technical Information
POWER
ELEVATI ON GYROINTERNAL SENSOR SKEW MOTOR
ELEVATION & AZ IMUTH MOTORS
AZIMUTH/ROLL GYROLIMIT SWITCHES
FUSE
Limit
Switches
Internal
Sensor
Azimuth
Gyro
Elevation
Gyro
Power
Elevation & Azimuth
Motors
Skew MotorFuse
To LNB
BOTTOM
TOP
RF1 From IRD