TracVision G8 Owner's Manual

5.15 Replacing the Skew Motor
(Linear Quad LNB Systems Only)
1. Using a
7
16" wrench, carefully disconnect the four RF
cables from the LNB.
Figure 5-25
Linear Quad LNB/Feed Tube Assembly
2. Disconnect the elevation and azimuth gyro cables from
the in-line connectors.
3. Disconnect the skew motor cable from the PCB module.
Figure 5-26
Skew Motor Cable Connector on PCB Module
Maintenance
54-0198
113
RF Cable
Connectors
LNB
Skew
Motor
#8-32 Screws (x 4)
POWER
ELEVATION GYROINTERNAL SENSOR SKEW MOTOR
ELEVATION & AZI MUTH MOTORS
AZIMUTH/ROLL GYROLIMIT SWITCHES
FUSE
Skew Motor
Cable Connector
Gyro Cable