Use and Care Manual

Transporting the Mixer Operation
10
Disconnect the power cord. Hold the support
leg and dump handle and move as shown
below. Make sure there is no material in the
drum
Maintenance and Cleaning
Disconnect the power cord
1. Clean thoroughly aer each use. Remove all material
from the mixer
2. Lightly grease all moving parts
3. Keep the motor cooling ns clean and free of build up.
4. When cleaning the mixer, wipe the On/O switch
assembly and motor with a damp cloth. Do not spray
water directly onto this area. Protect motor and switch
assembly from rain.
When tilting the drum to pour
material, do so in a very smooth
manner. is keeps the mixer
balanced and upright.
1. Position the mixer on a level surface. (NOTE:
Maximum slope is 5 degrees. Before lling the
drum, make sure the mixer can empty into a wheel
barrow).
2. Use a 3 prong, grounded, 110V/120V power con-
nection. Although the minimum gauges are listed
below, we recommend that a 14 gauge(AWG) wire
be used for all lengths.
3. While the drum is rotating add water, material
and aggregate. Secure the stability bolt prior to
drum rotation.
4. To pour the material, elevate the dump handle
while the drum is rotating.
5. In the event of overheating and your motor shuts
down, turn o the On/O switch and unplug the
unit for 15 minutes. Aer the cooling period, plug
in the unit and press the Manual Reset ermal
Protector button, then the On/O switch to on.
25 50 100 150
18 16 16 14
120
0-6
Cord Length
(total feet)
AWG
(wire gauge Bolts)
Volts
Amphere
Rating