Security Datasheet
Table Of Contents
Test Report
No.C230103003001-2
Date: Jan 05, 2023
Page 4 of 7
400 111 6218
Note: This Test report shall be invalid if it is not stamped with the special seal for testing. Only responsible for the tested samples, invalid if rewritten, added and deleted.
This test report cannot be reproduced, except in full, without prior written permission of the Company. Any unauthorized alteration, forgery or falsification of the content or
appearance of this report is unlawful and offenders may be prosecuted to the fullest extent of the law. Any demurral to the content of test report, please propose in 15 days
after the report’s sending out, it will not be accepted after this date.
Eurones (Dongguan) Consumer Products Testing Service Co., Ltd.
Tel: (86-769) 38937858 Fax: (86-769) 38937859 Http:// www.cpstlab.com
Room 1092, No.12, East of Houjie Avenue, Houjie, Dongguan, Guangdong, China
Postcode: 523945 E-mail: service@cpstlab.com
Section 6 - Accidental Release Measures
Personal precautions:If the cell is released, remove personnel from area until fumes dissipate. Provide
maximum ventilation to clear out hazardous gases. The preferred responseis to leave the area and allow the
vapors to dissipate. Avoid skin and eyes contact or inhalation of vapors. Remove spilled liquid with absorbent and
incinerated. If leakage of the cell happens, liquid could be absorbed wit sand, earth or other inert substance and
contaminated area should be ventilated meantime.
Environment precautions:Make an limitation for burning and throwing into garbage. Do not flush into surface
water.
Section 7 - Handling and Storage
Handling: Avoid mechanical damage or battery power abuse. Don't make the battery short. Don’t hit or puncture
the battery, or immerse the battery in the liquid. Don’t disassemble the battery or the battery into the fire. Don’t
store together with the metal, or make the positive and negative pole short.
Storage: Stored in a cool, dry, ventilated place with small change temperature. Don’t store batteries in high
temperature places with fire source. Don't expose the batteries directly to the sun for a long time.
Section 8 - Exposure Controls, Personal Protection
Maximum admissible concentration: No standard yet
Monitoring Method: None.
Engineering Control: To supply with sufficient air exhaust.
Respiratory Protection: No necessary under normal use. In case electrolyte leakage from the cell, protect hand
with chemical resistant rubber gloves. If cell is burning , leave the area immediately.
Eyes Protection: None required under normal conditions. Use approved chemical work safety goggles or face
shield, if handling a leaking or rupture cell.
Skin Protection: No necessary under normal use. Use rubber apron and protective working in case of handling
of a rupture cell.
Hands Protection: No necessary under normal use. In case of spilling, use PVC, neoprene or nitrile gloves of 15
miles(0.015 inch) or thicker.
Other Protections: Chemical resistance clothing is recommended along with eye wash station and safety shower
should be available. Work hygienic practices: Use good chemical hygiene practice. Wash hands after use and
before drinking, eating or smoking. Wash hands thoroughly after cleaning-up component spill caused by leaking
cell. No eating, drinking, or smoking in cell storage area.