10.5 ERROR CODE AND TROUBLE SHOOTINGS!
ERR.Code
Description
Solution
E01
Turn the knob during the heating process
Restart the fixture and follow the procedure.
E02
Hot Pocket has not removed the within
15min.
Restart the fixture and follow the procedure.
E04
HP read failed
Restart the fixture and re-insert HP pocket
E05
There is no phone in the HP module
Pull-out HP pocket and place phone onto it
E51
Invalid HP module
Restart the fixture and replace HP pocket
E37
NB thermocouple anomaly
Restart the fixture, if cannot resolve the
problem, replace new NB module.
E38
HP thermocouple anomaly
Restart the fixture and replace HP if needed
E57
NB Heater Open Circuit
Restart the fixture, if cannot resolve the
problem, replace new NB module.
E58
HP Heater Open Circuit
Restart the fixture and replace HP if needed
E62
NB temperature 100 degrees over limit
detected.
Replace new NB module.
E63
HP temperature 100 degrees over limit
detected.
Replace new HP.
E67
NB Heater Short Circuit
Restart the fixture, if cannot resolve the
problem, replace new NB module.
E68
HP Heater Short Circuit
Restart the fixture and replace HP if needed
E72
NB Thermocouple Attachment Anomaly
Replace new NB module.
E73
HP Thermocouple Attachment Anomaly
Restart the fixture and replace HP if needed
E76
NB temperature beyond the set range
detected
Restart the fixture, if cannot recover the
problem, replace new NB module.
E77
HP temperature beyond the set range
detected
Restart the fixture, if cannot recover the
problem, replace new HP.