Datasheet

Number of digital input channels 1
Input type 24 V control voltage (e.g. for power-good signal of a UPS)
Input thresholds approx. 3.0V (0 -> 1) / 2.3V (1 -> 0)
Input protection against overvoltage, negative voltages
Number of digital output channels 1
Output type
Relay contact, approval up to 30 V switching voltage (e.g. for
power supply of a router)
Maximum current load of the contact 2A @ 30V DC (resistive load!)
Software integration of input and output
Via GPIOs and process image. Output is optionally switched by
hardware watchdog
Hardware watchdog functionality
Can be disabled by bridging the 4-pole screw-type terminal. Re-
set by toggling a GPIO or alternatively a bit in the process image
Hardware watchdog intervall Trigger after approx. 60 seconds without toggling the reset bit
Compatible modules for system expansion
All RevPi IO modules and RevPi Gate modules can be connected
via the PiBridge system bus. Various transceiver modules can be
connected via the ConBridge system bus.
ESD protection
4 kV / 8 kV (according to EN61131-2 and IEC 61000-6-2)
EMI tests Passed (according to EN61131-2 and IEC 61000-6-2)
Surge/Burst tests Passed (according to EN61131-2 and IEC 61000-6-2)
Buer time RTC min. 24 h
Optical indicator 6 status LEDs (bi-color), two of them freely programmable
RoHS conformity Yes
CE conformity Yes
UL certication Yes, UL-File-No. E494534
Technical Data
RevPi Connect+
Article No.: 100302 (8 GB version)
Article No.: 100303 (16 GB version)
Article No.: 100304 (32 GB version)
Version: EN 1.2
page 2/2Errors excepted and possible alterations without prior notice.
KUNBUS GmbH, Heerweg 15C, 73770 Denkendorf, Germany | Tel: +49 (0)711 300 20 678 | Fax: +49 (0)711 300 20 677 | Email: info@kunbus.com | Web: www.kunbus.com