Instructions

NetTEST II Menu Guide
© KUNBUS 19
5.2.1.5 Generate livelist
Figure 11: Screen ‘Generate livelist’
In the menu Generate livelist, NetTEST II scans all possible
bus addresses from 0....126 for PROFIBUS DP Slave
participants. For this, a FDL request is effected several times
on each address. If a device answers with OK, its bus address
appears on the display. The unit counter is incremented by one.
To ensure that also extremely slow units are recognized, the
test takes approx. 30 seconds. Should all connected units
already be recognized, the user can truncate the test with .
Should there be more units than depictable on one display
screen, the user can scroll through after the test with
keys.
To be able to execute further tests, Generate livelist must by all
means be terminated by . Only then the recognized units are
registered in the internal memory, so that for these in the
following test, a Slave_Diag_Req can be run. If the test is quit
by , no slave diagnosis can be executed afterwards!