Instructions

Gateway component for DeviceNetTM 31 / 38
17 Production
inhibit time
UINT Defines the minimum time
between the data produc-
tions.
This attribute is necessary
for all I/O client connections.
Excluded from this are con-
nections with cyclical pro-
duction triggers.
Instance 10…12
# Name Access Type Description
1 State Get USINT State of the object
3: Established
5: Delete latent objects
2 Instance type Get USINT Indicates whether it is an I/
O connection or explicit
connection.
3 Transport-
Class trigger
Get BYTE Defines the behavior of the
connection
4 DeviceNet
produced
connection id
Get UINT Positioned in CAN identifier
field if data is transmitted
via the existing connection
in a DeviceNet- Subnet.
5 DeviceNet
consumed
connection id
Get UINT Value is in the CAN Identi-
fier field. It signals that
messages can be received.
6 DeviceNet
initial comm
characteris-
tics
Get BYTE Defines the message group
of this connection based on
consumption and produc-
tion.
7 Produced
connection
size
Get UINT Maximum number of bytes
that were transmitted via
this connection
8 Consumed
connection
size
Get UINT Maximum number of bytes
that were received via this
connection
9 Expected
packet rate
Get/Set UINT Defines the timing of the
current connection
12 Watchdog
timeout action
Get/Set USINT Controls the behavior
during inactivity and
Watchdog Timeouts
Configuration