Instructions
Gateway component for DeviceNetTM
30 / 38
Instance 4
# Name Access Type Description
1 State Get USINT State of the object
3: Established
5: Delete latent objects
2 Instance type Get USINT Indicates whether it is an
I/O connection or explicit
connection.
3 Transport-
Class trigger
Get BYTE Defines the behavior of the
connection
4 DeviceNet
produced
connection id
Get UINT Positioned in CAN identifier
field if data is transmitted via
the existing connection in a
DeviceNet- Subnet.
5 DeviceNet
consumed
connection id
Get UINT Value is in the CAN Identifier
field. It signals that mes-
sages can be received.
6 DeviceNet
initial comm
characteris-
tics
Get BYTE Defines the message group
of this connection based on
consumption and production.
7 Produced
connection
size
Get UINT Maximum number of bytes
that were transmitted via this
connection
8 Consumed
connection
size
Get UINT Maximum number of bytes
that were received via this
connection
9 Expected
packet rate
Get/Set UINT Defines the timing of the cur-
rent connection
12 Watchdog
timeout action
Get/Set USINT Controls the behavior during
inactivity and Watchdog
Timeouts
13 Produced
connection
path length
UINT Number of bytes of the
attribute "Produced_connec-
tion_path"
14 Produced
connection
path
Packed
EPATH
Displays the application ob-
ject(s) whose data was pro-
duced in the current connec-
tion.
15 Consumed
connection
path length
UINT Number of bytes of the at-
tribute "Consumed_connec-
tion_path"
16 Consumed
connection
path
Packed
EPATH
Displays the application ob-
ject(s) whose data was used
in the current connection.
Configuration