Brochure
Heavy duty linear solenoid RM 040
Weight:
Complete
solenoid: appr. 380 g
Armature: appr. 60 g
Standard:
Voltage: 24 V DC
Flying leads: 10 cm
Thermal stability: F (max. permissible
temperature = 155 °C)
Insulation group
according to: VDE 0110 C 300
Test voltage: 2500 V (eff)
Service-free armature bearing (plain
bearing) for maximum durability.
Stroke of version with standard stroke
limiter: 8 mm.
Return spring optional.
Force vs. Stroke diagramm F = f (s)
Force measured when operating in horizontal
position, at 90 % rated voltage and with winding at
operating temperature
stroke s = 0 corresponds to armature in
fully home position
Hochleistungs-Hubmagnet RM 040
Gewicht:
Magnet: ca. 380 g
Anker: ca. 60 g
Standard:
Spannung: 24 V DC
Litze: 10 cm
Thermische
Klasse: F (T
grenz
= 155 °C)
Isolationsgruppe
nach: VDE 0110 C 300
Prüfspannung: 2500 V (eff)
Wartungsfreie Ankerlagerung
(Gleitlager) für höchste Lebensdauer.
Bei Ausführung mit Standard-Hub-
begrenzung Hub 8 mm.
In Sonderausführung mit eingebauter
Rückholfeder lieferbar.
Kraft-Weg-Diagramm F = f (s)
Kraft bei waagerechter Bewegungsrichtung und
bei 90 % Nennspannung und betriebswarmer
Wicklung
Hub s = 0 entspricht dem angezogenen,
bestromten Zustand
Hochleistungs-Hubmagnet
RM 040
Heavy Duty Linear Solenoid
RM 040
KUHNKE Magnetkatalog 01/10
114
KUHNKE Solenoid Catalogue 01/10
RM040
24VDC100 %ED
Zul. rel. Einschaltdauer (ED)
2)
% 100 40 25 15 5 % Perm. duty cycle (ED)
2)
Nennaufnahme P
n
Anzugszeit (ED)
W
ms
11
36
21 41 67 161
11
W
ms
Nominal coil power P
n
Actuation time (ED)
2)
Bei Montage auf eine Kühlfläche ist eine höhere
ED zulässig (bitte anfragen)
2)
If solenoid is mounted directly onto a flat metal
surface, an increase in relative duty cycle is
permissible (please ask for advice)
0123456789
10
1
2
4
6
5
%ED
F/N
100
80
60
40
20
10
8
s/mm
100
40
25
15