Dimensions Guide
FOR MORE DETAILS AND INFORMATION, PLEASE VISIT OUR WEBSITE WWW.KUCHT.COM
INSTALLATION GUIDE AND USER MANUAL
Installation Introduction 
16 
Electrical Grounding Instruction: 
1. The power cord is equipped with a three-prong (grounding) plug which mates with a 
standard three-prong grounding wall receptacle  to  minimize  the  possibility  of 
electrical shock hazard from the range.   
2. All  cord connected  appliance  shall  include instructions  relative  to  location  of  the 
wall receptacle and a warning to the user to disconnect the electrical supply before 
serving the appliance. 
3. Where a standard two-prong wall receptacle is encountered, it is the responsibility 
and  obligation  of  the  customer  to  have  it  replaced  with  a  properly  grounded 
three-prong wall receptacle. Do not cut or remove the grounding prong from the 
power cord.   
CAUTION:Label  all  wires  prior  to  disconnection  when  servicing  controls.  Wiring 
errors  can  cause  improper  and  dangerous  operation.  Verify  proper  operation  after 
servicing. 
Connect Range to Gas Supply
1. Install a manual gas line shut-off valve in the gas line in an easily accessed location 
outside the range in the gas piping external to the appliance for
 the purpose of turning 
on or shutting off gas to the appliance.
2.
Install  male 
1
/
2
”  flare  union  adapter  to 
1
/
2
”  NPT  internal  thread  elbow  at  inlet  of 
regulator. On models equipped with standard twin burners, install the male pipe thread 
end of the 
1
/
2
” flare union adapter to the 
1
/
2
” NPT internal thread at inlet of pressure 
regulator. Use a wrench on the regulator fitting to avoid damage.
3.
Install male 
1
/
2
” or 
3
/
4
” flare union adapter to the NPT internal thread of the manual 
shut-off valve, taking care to secure the shut-off valve to keep it from turning.
4.
The gas supply pressure for checking the regulator setting is 6 in.w.c. (Nature Gas) 
and 11 inch.w.c. (LP gas) connect flexible gas line connector to the regulator on the 
range. Position range to permit connection at the shut-off valve.
This indoor gas cooking appliance is equipped with a three-prong(grounding) plug 
for  your  protection  against  shock  hazard  and  should  be  plugged  directly  into  a 
properly grounded three-pronged receptacle.   
DO NOT cut or remove the grounding prong from the plug. 