PRESSURE REGULATOR
Since service pressure may fluctuate with local demand, every gas
cooking appliance must be equipped with a pressure regulator on
the incoming service line for safe and efficient operation.
The pressure regulator shipped with the appliance has two female
threads 34" NPT. The regulator shall be installed properly in order to
be accessible when the appliance is installed in its final position.
Manifold pressure should be checked with a manometer and comply
with the values indicated below:
Natural gas -> 4.0" W.c.P.
LP/Propane -> 10.0" W.C.P.
Incoming line pressure upstream from the regulator must be 1" W.c.P.
higher than the manifold pressure in order to check the regulator.
The regulator used on this range can withstand a maximum input
pressure of 1/2 PSI (13.8" w.c. or 3,5 kPa) If the line pressure exceeds
that amount, a step-down regulator is required
The appliance, its individual shut-off valve, and the pressure regulator
must be disconnected from the gas line during any pressure testing of
that system at pressures in excess of 1/2 PSI (13.8" w.c. or 3,5 kPa).
The individual manual shut-off valve must be in the OFF position during
any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 PSI (13.8" w.c. or 3,5 kPa)..