Installation Guide
MANUAL SHUT-OFF VALVE
THIS VALVE IS NOT SHIPPED WITH THE APPLIANCE AND MUST BE
SUPPLIED BY THE INSTALLER.
The manual shut-off valve must be installed in the gas service line
between the gas hook-up on the wall and the appliance inlet, in a
position where it can be reached quickly in the event of an emergency.
In Massachusetts: A T handle type manual gas valve must be
installed in the gas supply line to this appliance.
FLEXIBLE CONNECTIONS
In case of installation with flexible couplings and/or quick-disconnect
fittings, the installer must use a heavy-duty, AGA design-certified
commercial flexible connector of at least 1/2" (1.3 cm) ID NPT
(with suitable strain reliefs) in compliance with ANSI Z21.41 and
Z21.69 standards.
In Massachusetts: The unit must be installed with a 36" (3-foot) long
flexible gas connector.
In Canada: use CAN 1-6.10-88 metal connectors for gas appliances
and CAN 1-6.9 M79 quick disconnect device for use with gas fuel.
PRESSURE TEST-POINT STOPPER VALVE
To avoid gas leaks, the pressure test-point stopper valve and gasket
supplied with the range must be installed on the gas fitting at the
back of the range according to the diagram below
INSTALL GUIDE