ELECTRICAL REQUIREMENTS & SPECIFICATIONS
IMPORTANT: Observe all governing codes and ordinances.
It is the customer’s responsibility to contact a qualied electrical installer.
A 120 Volt, 60 Hz, AC only, fused electrical supply is required on a 15-amp circuit.
DO NOT have a fuse in the neutral or ground circuit.
The 3-prong outlet should be grounded. If the power cord plug is not used, the power cord’s green wire should be
connected to ground.
Check with a qualied electrician if you are not sure that the range hood is properly grounded.
DO NOT ground to a gas pipe.
The range hood must be connected with copper wire/plug only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through exible armored
or non-metallic sheathed copper cable. ETL listed strain relief must be provided at each end of the power supply cable.
ITEM Unit Parameter
Rated Voltage V 110
Rated Frequency Hz 50
Motor Power W 50
Lamp Power W ≤2x1.5
Air Pressure Pa >160
Noise Level dB(A) <67
Air Output Diameter mm 150