Voltage / Current Loading
240 V AC/DC, max. 16 A
Power transmission, option 1
(depending on option)
240 V AC/DC, max. 20 A
Power transmission, option 2
48 V AC/DC, max. 2 A
Signal / data transmission
Contact resistance
(1)
≤ 1 Ohm
Power transmission
≤ 0,1 Ohm
Signal / data transmission
Contact material
Copper / bronze
Power transmission
Silver / precious metal
Signal / data transmission
Insulation resistance
10³ MOhm at 500 V DC
Dielectric strength
1000 V eff. (60 sec.)
Rotational speed
max. 500 min
-1
Operating temperature
0 ... +75 °C [+32°F ...+167°F]
Protection class
IP64
Maintenance intervals
See Installations- and Maintenance Instructions
Installation requirements:
Machine shaft: nominal diameter D h7. Penetration depth to be at least 50mm.
Anti-rotation: stator shall be secured from turning using the torque coupling never use a fixed connection for that.
Installation position: horizontal mounting, the slip ring shall be mounted with the maintenance window facing down.
IP protection: ensure completeness and correct installation of all gaskets supplied. Fitting gap hollow shaft / shaft shall
be sealed by the customer.
Deviating installations and mountings require prior consultation with the manufacturer.
(1)
signal: 2-wire resistance measurement, room temperature, digital multimeter 6 ½ digits or equivalent, values w/o test leads;
power: voltage measurement, room temperature, DC series connection, ohmic resistance, min 4A test current