Datasheet
291www.kuebler.com10/2010
Inclinometers
Analogue
Mechanical characteristics
Interface characteristics
General electrical characteristics
Connection M12connector
Weight 50 g
Protection EN 60529 IP68
Working temperature range -30…+70°C
Materials plasticPBT-GF20-V0
Shock resistance 30g,11ms
Vibration resistance
55 Hz (1 mm)
Dimensions 60 x 30 x 20 mm
Voltage output
at U
B
10 ... 30 V DC
0.1 ... 4.9 V
short-circuit protected to U
B
at U
B
5 V DC 2 ... 98%
ratiometric (in relation to UB)
Load resistance
voltage output ≥ 40 kΩ
Output impedance
voltage output 99…105 Ω
Current output 4...20 mA
Load resistance current output ≤ 200 Ω
Supply voltage 5 V DC +/-0.25 V or 10 ... 30 V DC
(depending on version)
Power consumption (no load) ≤ 20 mA
Reverse polarity protection (U
B
) yes
Measuring axes 2 (X/Y)
Measuring range ±10°,±45°,±60°
Resolution for version ±10° ≤ 0.05°
for version ±45° ≤ 0.1°
for version ±60° ≤ 0.15°
Repeat accuracy ≤ 0.2% of measuring range
≤ 0.1% after a warm-up period
of 30 min
Absolute accuracy
for version ±10° 0.3°
for version ±45° and ±60° 0.5°
Cross sensitivity 3%
Temperature drift
for version ±10° typ. 0.01°/K
for version ±45° and ±60° 0.03°/K
Reaction time 0.1 s
Timethattheoutputsignalrequiresto
reach90%fullscale,iftheangleis
changed from -60° to +60°
Zero point adjustment
for version ±10° ± 5°
for version ±45° and ±60° ± 15°
CE compliant acc. to EN 61362-2-3
EMCrequirementsfortransducers
Inclinometers
Connections
ext.teach:ifthisinputisconnectedto0V,thenthe
output of the inclinometer is reset to 0°.
Terminal assignment
Direction of Inclination Dimensions
IS40Inclinometer