Datasheet

125125
91 [3.583]
4,25 [0.167]
max. 10,5 [0.413]
7 [0.276]
45 [1.77]
48 [1.89]
48 [1.89]
15,5 [0.61]
91
4,25
max. 10,5
7
45
48
48
15,5
45
+0,6
[1.772
+0.024
]
45
+0,6
[1.772
+0.024
]
www.kuebler.com© Fritz Kübler GmbH, subject to errors and changes. 03/2013
Preset
counters
Dimensions in mm [inch]
Count inputs A and B
Polarity of the inputs programmable for all inputs
incommon,NPN/PNP
Input resistance 10 kΩ
Count frequency max. 5 kHz
(details see manual) can be
damped to 30 Hz
(mechanical contacts)
Control / Reset input
Lock,Reset
Min pulse duration of
signal and control inputs
statical
/1 ms
Switching levels 4...30VDC: low 0...2VDC
with AC/DC supply high 3.5 ... 30 V DC
Pulse shape variable,
Schmitt-Trigger
characteristics
Switching voltage max. 250 V AC / 110 V DC
Switching current max. 3 A AC/DC
min. 30 mA DC
Switching capacity max. 750 VA / 90 W
Output 1
Mech. service life (switching cycles) 2 x 10
7
N°ofswitchingcyclesat3A/250VAC 1x10
5
N°ofswitchingcyclesat3A/30VDC 1x10
5
Relaywithclosingcontact,progr.normalclosedornormalopen.
Output 2
Mech. service life (switching cycles) 20 x 10
6
N°ofswitchingcyclesat3A/250VAC 5x10
4
N°ofswitchingcyclesat3A/30VDC 5x10
4
Relaywithchangeovercontact
Reaction time of the outputs pulse counter < 15 ms
timer < 10 ms
Inputs Outputs
Dimensions
Terminal assignment
Output1
Output2
Power supply
Panel
cut-out
Pin Signal and control inputs
1 Sennsor power supply
2 GND(0VDC)
3 INPA(SignalinputA)
4 INPB(SignalinputB)
5 RESET(Resetinput)
6 LOCK(Keylockinginput)
7 n. c.
8 n. c.
Pin Version with relays
9 RelaycontactC.
10 RelaycontactN.O.
11 RelaycontactC.
12 RelaycontactN.O.
13 RelaycontactN.C.
14 AC:115/230VACN~
DC:11...30VDC
15 AC:115/230VACL~
DC:GND(0VDC)
Preset counters, electronic
LCD preset counters Codix 907 / 9081 or 2 presets – pulse, time – 5 kHz (AC+DC)