User Manual

6
Main technical features:
Display: LCD, 8 decades, height of the figures 8 mm.
Display range:
-9999999 ... 99999999
with leading zeros suppression.
Overflow: In case of a display range overflow, the
counter starts again from 0, but without
removing the leading zeros and activating
all decimal points.
In case of a display range underflow, the
counter starts again from 0 and displays the
minus sign, without removing the leading
zeros and activating all decimal points.
Keys: Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22,2
+0,3
x 45
+0,6
mm
Mounting depth: approximately 48 mm
Weight: approximately 50 g
Protection level: IP65 on the front side
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: 4,0 mm
2
single-wire
2,5 mm
2
thin wire
AWG 12
Connection diameter:
0,4 ... 2,3 mm single-wire
AWG 28-12
EMC: Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2
Low Voltage Directive (for the AC models):
EN 61010 Part 1 ; overvoltage category 2,
contamination level 2
Power supply:
Non-replaceable lithium battery
(lifetime approximately, 8 years at 20°C)
Working temperature:
–10 ... +55 °C, relative humidity < 85%,
without condensation
Operating temperature:
–10 ... +60 °C
Storage temperature:
–20 ... +70°C
Backlighting:
external electrical source
(24 V DC ±20 %, 50 mA)
Screw terminals 1 and 2:
Function and max. frequences(Pulse/Pause 1:1)
see Table 2
NPN : active for negative edge
Input resistance: approximately 1 MOhm
Low level: 0 ... 0,7 V DC
High level: 3 ... 30 V DC
PNP : active for positive edge
Input resistance: approximately. 100 kOhm
Low level: 0 .. 0,7 V DC
High level: 4 .. 30 V DC
Table 2
Input specification, pin assignment and adjustable operating modes (DC versions).
A control input (screw terminal 5) allows adjusting the operating mode.
Screw terminal Nr. 1 Nr. 2 Nr. 3 Nr. 4 Nr. 5 Nr. 6 Nr. 7
not active
=
adding
contact with
GND =
subtracting
6.130.012.8x0
6.130.012.8x2
6.131.012.8x0
6.131.012.8x1
6.133.012.8x0
6.133.012.8x1
07 kHz
12 kHz
07 kHz
12 kHz
03 kHz
06 kHz
NPN
NPN
PNP
NPN
PNP
30 Hz NPN
NPN
07 kHz
12 kHz
03 kHz
06 kHz
NPN
PNP
NPN
PNP
NPN reset input
NPN reset key locking input,
Contact with GND, key free..
not active
=
Cnt.Dr Mode
contact with
GND =
Up.Dn Mode
not active
=
Quad Mode
contact with
GND =
Quad2 Mode
GND = 0 V DC
Backlighting (–)
Designation
Model
INP A INP B Reset Reset
Enable
Control inputs for operating
mode (Mode)
GND BL
Nr. 8
BL
+
Backlighting (+)
PNP