Datasheet

3/2005
www.kuebler.com
85
Display counter
X: 5 = no backlight
X: 6 = with backlight
1): one-channel, adding or subtracting counting
2): counting input with counting direction input
3): one adding and one subtracting counting input
(differential mode)
4): Phase discriminator for incremental encoders with
single processing
5): Phase discriminator for incremental encoders with
double processing
Type Input type Count inputs
INP A INP B
6.130.012.8x0 Count
1)
0 ... 0,7 V DC count NPN 7 kHz 0 ... 0,7 V DC count NPN 30 Hz
6.130.012.8x2 4 ... 30 V DC count PNP 12 kHz0 0 ... 0,7 V DC count NPN
6.130.012.8x3 10 ... 260 V AC/DC count AC/DC 30 Hz 10 ... 260 V AC/DC reset AC/DC
6.131.012.8x0 Cnt.Dir
2)
/Up.Dn
3)
0 ... 0,7 V DC count NPN 7 kHz 0 ... 0,7 V DC count/direction NPN 7 kHz
6.131.012.8x1 4 ... 30 V DC count PNP 12 kHz 4 ... 30 V DC count/direction PNP 12 kHz
6.131.012.8x3 Up.Dn
3)
10 ... 260 V AC/DC count AC/DC 30 Hz 10 ... 260 V AC/DC count AC/DC 30 Hz
6.132.012.8x3 Cnt.Dir
2)
10 ... 260 V AC/DC direction AC/DC 30 Hz 10 ... 260 V AC/DC count AC/DC 30 Hz
6.133.012.8x0 Quad
4)
/Quad2
5)
0 ... 0,7 V DC channel A NPN 3 kHz 0 ... 0,7 V DC channel B NPN 3 kHz
6.133.012.8x1 4 ... 30 V DC channel A PNP 6 kHz 4 ... 30 V DC channel B PNP 6 kHz
OOrrddeerr iinnffoorrmmaattiioonn::
LLCCDD DDiissppllaayy ccoouunntteerr CCOODDIIXX 113300//113311//113322//113333
Display counter electronic
DDiimmeennssiioonnss::
Countersinking Af3, DIN 74
1
Panel cut-out
Panel cut-out
DDiimmeennssiioonnss ffoorr bbeezzeellss ((iinncclluuddeedd iinn ssccooppee ooff ddeelliivveerryy ))::
– Digital display
– Panel mounting clip
– Bezel for screw mounting (56 x 40),
panel cut out 50 x 25 mm
– Bezel for clip mounting(53 x 28),
panel cut out 50 x 25 mm
Seal
– Operating instructions.
SSccooppee ooff ddeelliivveerryy::