Datasheet

136136
STOP
STOP
www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 10/2016
Pulse counter
Count with direction mode
Difference mode
Quadrature mode quad / quad2 / quad4
Add, Sub, automatic reset
2-input adding mode A+B
Ratio measurement A/B
Multi-range power supply for AC or DC
Percentage difference measurement
(A-B)/A x 100 %
Batch counting
Totalizer (Overall total)
Multiplication and division factor (up to 99.9999)
Set value
Step or tracking preset
Application examples
CountDir + Add
Roller shutter door with automatic shut-off
Quad + Add
Running direction and position on milling machines, Limit switch monitoring
UpDown + Add
Automatic subtraction of faulty or reject parts from the total piece count
CountDir + Batch
Logging of piece numbers and packing units plus control of replenishment of
packing cartons
UpUp + Add
Adding up of two parallel or staggered production lines
Quad + Add tot
Cut-to-length with overall total count and control of the machine
Functions / count modes
Preset counters, electronic
LED preset counters Codix 560
Multifunctional – pulse, frequency, time –
65
kHz, 2 presets (AC+DC)