Datasheet

225www.kuebler.com© Fritz Kübler GmbH, subject to errors and changes. 10/2016
Frequency displ.
Tachometers
Accessories Dimensions in mm [inch] Order no.
Mounting frame
with cut-out 92 x 45 [3.62 x 1.77]
for snap-on mounting on 35 [1.38] top-hat DIN rail,
for counters 96 x 48 [3.74 x 1.89]
grey G300005
Suitable gaskets as well as further accessories can be found in the accessories section or in the accessories area of our website at: www.kuebler.com/accessories.
Frequency displays / tachometers
Applications for speed and frequency displays
Rotary speed applications, e.g. OEM equipment
or retrofitting to drilling machines
OEM equipment for flow rate measuring, e.g.
current flow rate; production data such as
volume/time
Speed applications on motors, turbines,
machines; feed-rate measurement
Recording of production rates
Frequency measurement
Display 6 digit, red 7 segment
LED display; 14 mm [0.55“] high
Data backup EEPROM
Operating temperature -20°C ... +65°C [-4°F ... +149°F]
(non-condensing)
Storage temperature -20°C ... +70°C [-4°F ... +158°F]
Altitude up to 2000 m [6562‘]
Housing front panel mount 96 x 48 mm
[3.74 x 1.89“] acc. to DIN 43700;
RAL 7021, dark grey
Protection IP65 (front side)
Weight approx. 150 g [5.29 oz]
Sensors power supply (AC version) 24 V DC ±15 %/100 mA
Output power optocoupler max. 30 V DC, 10 mA
Power supply 10 ... 30 V DC, with reverse polarity
protection
100 ... 240 V AC, ±10 %
Current consumption max. 50 mA, 6 VA
EMC standards EN 55011 class B,
EN 61000-6-2, EN 61000-6-3
Device safety designed to EN 61010 part 1
protection class 2
application area pollution level 2
UL approval file E128604
General technical data
Technical data
Mechanical characteristics
Outputs
Inputs
Electrical characteristics
Polarity of inputs programmable, NPN or PNP
for all inputs
Input resistance approx. 5 kΩ
Counting frequency
1)
max. 60 kHz,
can be damped to 30 Hz
Measurement principle / Accuracy Gate and/or time interval
(period duration) measurement,
with high accuracy < 0.1 % (HRA)
Input switching level standard version (HTL)
DC power supply LOW 0 ... 0.2 x U
B
[V DC]
HIGH 0.6 x U
B
... 30 V DC
AC power supply LOW 0 ... 4 V DC
HIGH 12 ... 30 V DC
Input switching level at 4 ... 30 V DC
LOW 0 ... 2 V DC
HIGH 4 ... 30 V DC
1) Please refer to the manual
LED frequency displays Codix 542Measuring range 1/min or 1/sec HRA-measurement (AC+DC)
Mass flow rate Drilling machine head, rotary speed Production rate