Datasheet

59www.kuebler.com
+Ub
GN
D
24 [0.945]
48 [1.89]
47.7 [1.878] 3 [0.118]
2.8 [0.11]
max. 19.3 [0.76]
22 x 45
[0.866 x 1.772]
22.2
+0.3
[0.874
+0.012
]
45
+0.6
[1.772
+0.024
]
© Fritz Kübler GmbH, subject to errors and changes. 10/2016
Pulse
counters
Display and inquiry mode - service counter
If the reset key is not released by means of the activation input of pin 6, pressing the
key makes the following functions available to the user.
Press 1 x: The text “SErViCE“ is displayed
Press 2 x: The following Service value is displayed
Press 3 x: The text “PrESErV“ is displayed
Press 4 x: The following pre-service value is displayed
Press 5 x: The current value is displayed
For the service counters, the values counted remain stored, the service values
are incremented by the stored preset value when resetting. E.g. service value
5000 pulses, counter count when resetting 5100 pulses, new service value 10100.
Ride counting and
service intervals
Number of cuts and
knife replacement
Total quantity and
service interval
Applications
Pulse counters, electronic
Terminal assignment
PIN Description Standard counter Service counter
Power supply
1 +U
B
10 ... 30 V DC 10 ... 30 V DC
2 0 V DC, GND GND GND
Inputs
3 0 V DC, GND GND GND
4 Fast counting input INP PNP INP PNP
5 Slow counting input INP NPN INP NPN
6 Reset enable input RESET MANUAL RESET MANUAL
ENABLE ENABLE
7 Reset input RESET RESET
Output
8 NPN output n.c. OUT
Pin 8: NPN output, Open Collector
for Codix 142
Output 8 is used only with
Codix 142 as a NPN output
RI
Pin 2 or 3
Panel cut-out
LCD pulse counters Codix 140 / 142Adding counter / service counter (DC)
Dimensions
Dimensions in mm [inch]