Manual
  Page 1 | ENG
english
Operating instructions 
LCD Display counters 
Codix 130/131/132/133 
1. Description
The Codix 13X display counters are battery-powered. 
They are controlled by contact or voltage pulses. They 
may be used in various applications, like e. g. totalising, 
parts counting, position acquisition, differential counting, 
etc. In addition, the various models with specific input 
types may be extended using control inputs to select 
operatin modes and set for almost any application 
thanks to adjustable operating modes.
1.1 Preface
Please read this instruction manual entire-
ly and carefully before installation and 
start-up. Please observe all warnings and 
advice, both for your own safety and for 
general plant safety. If the device is not 
used in accordance with this instruction 
manual, then the intended protection can be 
impaired.
1.2 Safety Instructions and Warnings
Please use the device only if its technical 
condition is perfect. It should be used only 
for its intended purpose. Please bear in 
mind safety aspects and potential dangers 
and adhere to the operating instructions at 
all times. 
Defective or damaged devices should be 
disconnected from the mains immediately 
and taken out of operation.
The device shall not be opened. Use the 
repair service of the manufacturer.
Only connect the device to the electricity 
networks provided to that purpose.
The safety of the system in which the device 
is integrated is the responsibility of the 
installer. 
Disconnect all electricity networks prior to 
any installation or maintenance work.
Use exclusively cables approved in your 
country and designed for your temperature 
and power ranges.
Installation and service work shall be carried 
out exclusively by qualified personnel.
The device must compulsorily be protected 
with approved external fuses. The value of 
these fuses can be found in the technical 
information.
This symbol is used on the device to remind 
of the existence of dangers, which are 
referred to in this manual.
1.3 Use according to the intended purpose
The display counter detects and measures pulses, 
times and frequencies up to max. 12 kHz and offers a 
wide variety of different operating modes. Use for any 
purpose over and beyond this will be deemed as not in 
accordance with its intended purpose and thus not com-
plying with the requirements. 
The application area for this device lies in industrial pro-
cesses and controls, in the fields of manufacturing lines 
for the metal, wood, plastics, paper, glass, textile and 
other like industries. Over-voltages at the terminals of 
the device must be kept within the limits of Over-voltage 
Category II.
The device must only be operated when mounted in 
a panel in the correct way and in accordance with the 
section “Technical Data”.
The device is not suitable for use in hazardous areas 
and for areas excluded in EN 61010 Part 1. If the 
device is used to monitor machines or processes in 
which, in the event of a failure of the device or an 
error made by the operator, there might be the risk of 
damaging the machine or causing an accident to the 
operators, it is your responsibility to take the appropriate 
safety measures. 
The device has been designed for indoor operation. 
It may nevertheless be used outdoors, provided the 
technical data is adhered to. In this case, take care to 
provide suitable UV protection.
1.4 Mounting in a control panel
Mount the device away from heat sources 
and avoid direct contact with corrosive liquids, 
hot steam or similar.
Provide a free space of 10 mm all around the 
device for its ventilation.
The device should be mounted so that the 
terminals are out of the reach of the operator 
and cannot be touched by him. When mount-
ing the device, consider the fact that only the 
front side is classified as accessible for the 
operator.
!
t
t
!
CAUTION