Datasheet
3www.kuebler.com© Fritz Kübler GmbH, subject to errors and changes. 03/2023 www.kuebler.com
Preset counters, electronic
LCD preset counters 9011 preset – pulse, time (battery)
Technical data
General technical data
Display
2 line LCD display, 6 digits 999999;
7 or 4.5 mm [0.28 or 0.18“] high
Operating temperature
-20 °C ... +65 °C [-4 °F ... +149 °F]
(non-condensing)
Storage temperature
-25 °C ... +70 °C [-13 °F ... +158 °F]
Relative humidity
< 85 % (non-condensing)
Altitude
up to 2000 m [6562‘]
Mechanical characteristics
Protection
IP65 (front side)
Weight
approx. 80 g
Electrical characteristics
Supply voltage
2 pcs user exchangeable lithium-
batteries type 1/2 AA lithium 3.6 V
Data retention
min. 8 years at 5 x 10
6
power
operations of the output relay
and an operating temperature of
25 °C [+104 °F]
Device safety designed to
protection class
application area
EN 61010-1, EN 61010-2-201
2 (front side)
pollution level 2
Inputs
Inputs
reset, count and key lock inputs
Polarity of the inputs
(for reset and count/start input)
12 ... 250 V AC/DC
NPN
bidirectional optocoupler input
NPN input activated by transistor or
contact
Keyboard lock input
connected to +3 V DC (terminal 1)
Min. pulse duration of the inputs
reset input
keyboard lock input
50 ms
15 ms
Switching levels of the inputs
12 ... 250 V AC/DC
NPN
LOW: < 1 V AC/DC
HIGH: 12 ... 250 V AC/DC
LOW: 0 ... 0.8 V DC
HIGH: 2.5 ... 5 V DC
Input frequency
max. 30 Hz
Input resistance
110 kΩ
Outputs
Output
bistable relay with potential
free
contact (
programmable as normally
closed or normally opened contact)
Max. switching voltage
250 V AC / 30 V DC
Max. switching current
2 A
Max. switching capacity
60 VA / 30 W
Output response time
< 20 ms, max. 4 Hz
Insulation coordination
basic insulation
Approvals
UL compliant in accordance with File no. E128604
CE compliant in accordance with
EMC Directive
RoHS Directive
Low Voltage Directive
2014/30/EU
2011/65/EU
2014/35/EU
UKCA compliant in accordance with
EMC Regulations
RoHS Regulations
Low Voltage Regulations
S.I. 2016/1091
S.I. 2012/3032
S.I. 2016/1101