3.2.1 System Configuration
The switch supports manual IP address setting. When IP address is changed, you must reboot the
switch to have the setting taken effect and use the new IP to browse for web management.
Parameter description:
MAC Address It is the Ethernet MAC address of the management agent in this switch.
Firmware Version The firmware version of this switch.
Hardware Version The hardware version of this switch.
Serial Number The serial number is assigned by the manufacturer.
IP Address Users can configure the IP settings and fill in new values. Default:
192.168.1.1
Subnet Mask Subnet mask is used to set the subnet mask value. Default: 255.255.255.0
Default Gateway Set an IP address for a gateway to handle those packets that do not meet
the routing rules predefined in the device. Default: 192.168.1.254
System Name Set a special name for this switch. Up to 16 characters are allowed in this
parameter. Any alphanumeric character and null are acceptable. Default:
Giga Switch
Password Set a password for this switch. Up to 16 characters are allowed in this
parameter. Any alphanumeric character is acceptable. Default: admin
Auto Logout Timer Set the auto-logout timer. The valid value is 0 ~ 60 in the unit of minute
and a decimal point is not allowed. The value 0 means auto-logout timer is
disabled. Default: 0