User's Manual
5. Press the [MENU] key to confirm and save.
6. Press the [EXIT] key to exit the menu.
-Time operation
In Time Operation (TO) mode, the scanner stops when it detects a signal, and after a factory preset time out, it
resumes scanning.
-Carrier operation
In Carrier Operation (CO) mode, the scanner stops when it detects a signal, and after a factory preset time
with no signal it resumes scanning.
-Search operation
In Search Operation (SE) mode, the scanner stops when it detects a signal. To resume scanning you must press
and hold the [*
] key again.
In the CPS Software Path: - Edit - Optional Features - Scan Mode, it can set three scan modes, and
program the desired scan mode and write it to the radio.