Datasheet

Siemens Matsushita Components 169
Technical data
Standards IEC 1071-1/2
EN 61071-1/2
VDE 0560 part 120 and 121
Dielectric dissipation factor tan δ
0
2 · 10
–4
Max. repetitive rate
of voltage rise (d
u
/d
t
)
max
Max. non-repetitive rate
of voltage rise (d
u
/d
t
)
s
Climatic data:
Min. operating temperature Θ
min
– 25 °C
Max. operating temperature Θ
max
+ 85 °C
Average relative humidity 95 %
Failure quota α
FQ(co)
300 failures per 10
9
component hours
Load duration
t
LD(co)
100 000 h
Storage temperature limit Θ
stg
– 55/+ 85 °C
IEC climatic category
(IEC 68-1 and 2)
25/085/56
Test A, cold
Test B, dry heat
Test Ca, damp heat, steady state
– 25 °C
+ 85 °C
56 days/40 °C/93 % rel. humidity
Values after test Ca:
Capacitance change
C
/
C
1 %
Insulation resistance
R
is
C
N
1 µF: 10 000 M
Self-discharge time constant τ =
R
is
·
CC
N
>1 µF: 10 000 s
Dissipation factor change tan δ≤1 · 10
–4
Test data:
AC test voltage between terminals
U
TT
1,25 ·
U
N
, 50 Hz, 10 s (or DC 1,75 ·
U
N
, 10 s)
Insulation resistance
R
is
C
N
1 µF: 10 000 M
Self-discharge time constant τ =
R
is
·
CC
N
>1 µF: 10 000 s
Dissipation factor (50 Hz) tan δ≤3
.
10
–4
î
C
----
I
S
C
----
B 25 835
Damping