MSDS
KRUD KUTTER® Decal & Adhesive Remover              6/08/11
North America    3/8 
Prevention of Fire and Explosion: Keep away from strong oxidizing agents. 
Storage: Keep container tightly closed. Store in original container. Keep out of reach of children. 
8  EXPOSURE CONTROLS / PERSONAL PROTECTION 
Industrial Exposures: 
Exposure Limits:  
Chemical Name  Source  Type  Exposure Limits Notes 
2-Butoxyethanol NIOSH IDLH  700 ppm Skin 
2-Butoxyethanol (EGBE)  ACGIH  TWA  20 ppm Irritation; 
CNS 
2-Butoxyethanol  OSHA  TWA  50 ppm Skin 
2-Butoxyethanol  Cal OSHA  TWA  25 ppm Skin 
D-Limonene AIHA WEELs 30 ppm -- 
Engineering Controls: Use process enclosures, local exhaust ventilation, or other engineering controls to 
keep airborne contaminants below established exposure limits. 
Respiratory Protection: If engineering controls do not maintain airborne concentrations below 
recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure 
limits have not been established), an approved respirator must be worn. In the United States of America, 
if respirators are used, a program should be instituted to assure compliance with OSHA Standard 63 FR 
1152, January 8, 1998. Respirator type: Air-purifying respirator with an appropriate, government 
approved (where applicable), air-purifying filter, cartridge or canister. Contact health and safety 
professional or manufacturer for specific information. 
Eye Protection: Wear splash goggles and a face shield where a splash hazard exists. 
Hand Protection: Wear chemical resistant gloves. 
Skin Protection: Wear protective clothing appropriate for the risk of exposure. 
Hygiene Measures: Eye wash, safety shower, washing facilities 
9  PHYSICAL AND CHEMICAL PROPERTIES 
Color: Clear orange 
Odor: Citrus 
Physical State: Liquid
pH: 3.5 
Boiling Point: No data available 
Melting Point: No data available 
Flash Point: > 93.3°C (estimated) 
Evaporation Rate: No data available
Flammability: No data available 
Flammability Limit – Upper (%): No data available 
Flammability Limit – Lower (%): No data available 