Owner's manual
70 Handbook BM 100 A
Other error markers not shown on the oscilloscope window (scroll screen to view):
Other Markers
Notes
ADC reference error ADC=Analog to Digital Converter
RAM error RAM=Random Access Memory
ROM error ROM=Read-Only Memory
EEPROM user error EEPROM=Electrically Erasable Programmable Read-Only Memory
EEPROM factory error
Strap table error Strap table=volume calibration input table
DAC error DAC=Digital to Analog Converter
Error markers detailed in items 1 to 5 above are the result of errors directly related to measurement
and may be solved by modifying the gauge settings. Other error markers relate to hardware errors
and should be solved with KROHNE service centre assistance.
Other functions available on the Oscilloscope window:
F1 – Help On-line help file
F3 – Exit Exit to real-time measurement main window
F4 – Zoom - Reduces the time slice scale
F5 – Zoom + Increases the time slice scale
F10 – Screen copy To select a directory and save the current screen as a bitmap file.
F9 – Colors Menu
Refer to section 9.4.7 for all information concerning this set of functions.
F10 – Screen copy Menu
To save a bitmap image of the active window.