How to configure displayed value and units
User Sub-menu 1.2 - Display Functions
These functions are used to choose the information to be displayed in operating mode:
the measurement function (distance, level, volume, etc.) and units (mm, ft., m3, etc.)
Display mode (1 (single) or 2 or more items in a repeating loop (cyclic mode))
Example procedure 2:
to modify display mode from “single” to “cyclic” to configure a repeating loop displaying more
than one piece of data,
to select Level and Distance and display each item for 5 seconds.
Step Action Press buttons to
finish step
Information displayed at the end of
each step
1 Start from Operating Mode
screen
n/a 6750
LEVEL mm
2 Go to fct. 1.2.1 from the
operating mode
→,→,↑,→
Fct. 1.2.1
DISP.MODE
3 Enter function 1.2.1
Display Mode (default
value: SINGL.MODE)
SINGL.MODE
4 Modify value to
CYCL.MODE
CYCL.MODE
5 Exit fct. 1.2.1data set field
and go to fct. 1.2.2
↵,↑
Fct. 1.2.2
DISPL.ITEM
6 Enter function 1.2.2
(Display Item) data set field
Default value: LEVEL
LEVEL
7 Select “DISTANCE”.
↑↑
DISTANCE
8 Press “RIGHT” to confirm
or cancel data item to be
added to display loop
No
9 Press “UP” to confirm
parameter
Yes
10 Exit data set field to
confirm. Go to to fct. 1.2.3
↵,↵,↑
Fct. 1.2.3
CYCLIC TIME
11 Enter function 1.2.3 data
set field (default value: 01).
Change to 05 seconds.
→,→,↑,↑,↑,↑
05
Sec
12 Exit data set field, function,
submenu and menu. Save
new configuration and
return to Operating Mode
↵,↵,↵,↵,↵
6750
LEVEL mm
The operator may display volume once the gauge is calibrated to measure volume in submenu