Manual

Installation and operating instructions
BATCHCONTROL
Object No
Index
Value (default)
Description
Dimension
Format
min
max
access
Descriptor
transfer
Description
35yxH Customer specific 32 bit memory (3 <= y <= 8)
35y1H 00h 6 Number of entries without byte - - r - -
35y1H 01H 0 Data format without byte 0 255 r - -
descriptor for data format bit n = 0:
byte n = long, bit n = 1: byte n =
float
35y1H 02H 0 Long no 1 without long
-2.1e9
-3.4e38
2.1e9
3.4e3
8
r/w - -
1. long (35y1.01) bit 0 = 0: long
(this parameter use the same
memory cell as 30y4.03)
(35y1.01) bit 0 = 1: float
35y1H 03H 0 Long no 2 without long
-2.1e9
-3.4e38
2.1e9
3.4e3
8
r/w - -
2. long (35y1.01) bit 1 = 0: long
(this parameter use the same
memory cell as 30y4.06)
(35y1.01) bit 1 = 1: float
35y1H 04H 0 Long no 3 without long
-2.1e9
-3.4e38
2.1e9
3.4e3
8
r/w - -
3. long (35y1.01) bit 2 = 0: long
(35y1.01) bit 2 = 1: float
35y1H 05H 0 Long no 4 without long
-2.1e9
-3.4e38
2.1e9
3.4e3
8
r/w - -
4. long (35y1.01) bit 3 = 0: long
(35y1.01) bit 3 = 1: float
35y1H 06H 0 Long no 5 without long
-2.1e9
-3.4e38
2.1e9
3.4e3
8
r/w - -
5. long (35y1.01) bit 4 = 0: long
(35y1.01) bit 4 = 1: float
3900H Software download
3900H 00H 1 Number of entries without byte - - r - -
3900H 01H 0 Software download without - - - w - -
Firmware download (only in
preoperation mode)
Download time (128kbyte):
20 kBaud: 149s
100 kBaud: 65.2s
250 kBaud: 47.0s
500 kBaud: 47.0s
1 Mbaud: 47.0s