Manual
Installation and operating instructions 40 BATCHCONTROL
Object No
Index
Value (default)
Description
Dimension
Format
min
max
access
Descriptor
transfer
Description
output
0 = activation of
message output
3093H 08H 0,3 Maximum tail time s float 0,005 10 r/w - d
Limit value for the tail time, status
info only
3093H 09H 0 Actual status without byte 0 1 r 94H -
Bit 0: 1 = Limit value overstepped,
0 = okay
3093H 0AH 4
Sending function for Index
09H
without byte 0 4 r/w - d
Sending function at change of
status
Bit 1-0: Priority
00 = PDO 0
01 = PDO 1
10 = PDO 2
11 = PDO 3
Bit 2: Activation of function
1 = no message
output
0 = activation of
message output
3093H 0BH 0,01 Maximum leakage volume l float 0,001 0,1 r/w - d
Leakage volume between two
batches, status info only
3093H 0CH 0 Actual status without byte 0 1 r 95H -
Bit 0: 1 = limit value overstepped, 0
= okay
3093H 0DH 4
Sending function for Index
0CH
without byte 0 4 r/w - d
Sending function at change of
status
Bit 1-0: Priority
00 = PDO 0
01 = PDO 1
10 = PDO 2
11 = PDO 3
Bit 2: Activation of function
1 = no message
output
0 = activation of
message output
3093H 0EH 0.002 Lower limit for volume flow l/s float -100 +100 r/w - d lower deviation of the set point
3093H 0FH 0 Actual status without byte 0 1 r A0H -
Bit 0: 1 = limit value understepped,
0 = okay
3093H 10H 4
Sending function for Index
0FH
without byte 0 4 r/w - d
Sending function at change of
status
Bit 1-0: Priority
00 = PDO 0
01 = PDO 1
10 = PDO 2
11 = PDO 3
Bit 2: activation of function
1 = no message
output
0 = activation of
message output
3093H 11H 0.002 Upper limit for volume flow l/s float -100 +100 r/w - d upper deviation of the set point
3093H 12H 0 Actual status without byte 0 1 r A1H -
Bit 0: 1 = limit value overstepped, 0
= okay
3093H 13H 4
Sending function for Index
12H
without byte 0 4 r/w - d
Sending function at change of
status
Bit 1-0: Priority
00 = PDO 0
01 = PDO 1
10 = PDO 2
11 = PDO 3
Bit 2: activation of function
1 = no message
output
0 = activation of
message output
3093H 14H 0 Reset emergency shut off without byte 0 1 w - d 0 = no action