Manual

Installation and operating instructions 22 BATCHCONTROL
Part D Technical Data, block diagram
and measuring principle
6 Technical data
6.1 Flow during filling, and fill volume
Meter size Optimum flowrate for filling
Filling times > 1.5 s,
filling volume .....
DN mm inches ml/s US Gal/min ml US Gal
2.5
1
/
10
3 - 10 0.048 - 0.159
10
0.003
4
1
/
8
10 - 30 0.159 - 0.476
20
0.005
6
1
/
4
20 - 60 0.317 - 0.951
40
0.011
10
3
/
8
60 - 200 0.951 - 3.170
100
0.026
15
1
/
2
150 - 500 2.378 - 7.925
200
0.053
25 1 400 - 1200 6.340 - 19.020
600
0.159
32 1
1
/
4
650 - 2250 10.300 - 35.663
975
0.257
40 1
1
/
2
1000 - 3000 15.850 - 47.551
1500
0.396
6.2 Flowmeter
Meter sizes
with venturi measuring tube DN 2.5, 4, 6, 10, 15, 25, 40 and
1
/
10
",
1
/
8
",
1
/
4
",
3
/
8
",
1
/
2
", 1",1
1
/
2
"
with straight tube (option) DN 15, 32 and
1
/
2
", 1
1
/
4
"
Connection sandwich (flangeless) type with precisely defined sealing faces,
centering devices and metallic stop face
Electrical conductivity 5 µS/cm (20 µS/cm for demineralized cold water)
Ambient temperature Process temperature
-25 to +40 °C / -13 to +104 °F -60 to +140 °C / -76 to +284 °F
-25 to +60 °C / -13 to +140 °F -60 to + 60 °C / -76 to +140 °F
(information on higher provided on request)
steam cleaning up to +150 °C / +302 °F (max. 1 hour)
Temperature shock resistance Temperature rising Temperature falling
sudden change T = 120 °C = 216 °F T = 90 °C = 162 °F
Temperature gradient 1 K/s = 1.8 °F/s
Operating pressure 40 bar / 580 psig
(10 bar / 145 psig for DN 15, 32 and
1
/
2
", 1
1
/
4
"
with straight measuring tube)
Electrode design fused-in-place electrodes
Protection category IP 67, equivalent to NEMA 6
(EN 60 529/IEC 529) (overall device, incl. signal converter)
Materials of construction
Housing stainless steel 1.4408 or 1.4404
Measuring tube fine-grain-stabilized, high-density HiTec ceramics,
purity 88 % Al
2
O
3
+ 12%ZrO
2
, CIP- and SIP-proof
Electrodes Cermet
Cover seal EPDM
6