ModBus Manual 0300 rev07 E 7.30855.35.00 Page 49 of 64
125 249 F32+R Batch stop: Override External Temperature 4 8 5 s
126 251 F32+R Batch stop: Override Density Temperature 4 2 5 s
127 253 F32+R Batch stop: Override Process Pressure 4 2 5 s
128 255 F32+R Batch stop: Override External Pressure 4 8 5 s
129 257 F32+R Batch stop: Override Densito Pressure 4 2 5 s
130 259 F32+R Batch stop: Override Density 4 2 5 s
131 261 F32+R Batch stop: Override Standard Density 4 2 5 s
132 263 F32+R Batch stop: Override External Viscosity 4 1 5 s
133 265 F32+R
Batch stop: Lowest measured Temperature (for high viscosity
applic.)
4 2 5 °C
134 267 F32+R
Batch stop: deviation % (worst case estimate due to batch
alarms)
5 4 %
135 269 F32+R
Batch live: deviation % (worst case estimate due to batch
alarms) during batch
5 4 %
136 271 F32+R Kinemat.Viscosity - temp corrected - (for ext. visc. input applic.) 1 cSt or 10-6 m2/s
137 273 F32+R
Check Modbus totalisers and batch 1+2 values on hold (see
Bool2075)
4 s, max 30s
8.8 Field 6 (Read Only ASCII Field 8 characters)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and
with functions 6 and 16 in Modbus master mode. This ASCII field is a 64 bit type.
By default the start addresses are mapped to address 4000 (default value)
start address
NotModiconComp
start address
ModiconComp
Type+Access
Description
Level
Level
Level
Remark
1 1 S32+RW
Ascii32 String Combination of four 8 char
strings for writing one long string to one address
(batch ticket print code 2221 2222 2223 2224) 4 6 To print in the batch ticket
1 1 S8+RW Ascii8 String 1 (batch ticket print code 2221)
4 6
To print in the batch ticket
2 5 S8+RW Ascii8 String 2 (batch ticket print code 2222)
4 6
To print in the batch ticket
2 9 S8+RW Ascii8 String 3 (batch ticket print code 2223)
4 6
To print in the batch ticket
3 13 S8+RW Ascii8 String 4 (batch ticket print code 2224)
4 6
To print in the batch ticket
8.9 Field 6 (Read Write ASCII Field 16 characters)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave mode and
with functions 6 and 16 in Modbus master mode. This ASCII field is a 128 bit type.
Starting addresses are mapped to address 14000 (default
start address
NotModiconComp
start address
ModiconComp
Data Type
Description
Level
Level
Level
Remark
1 1 S16+RW Ascii16 String 5 (batch ticket print code 2261)
4 6
To print in the batch ticket
2 9 S16+RW Ascii16 String 6 (batch ticket print code 2262)
4 6
To print in the batch ticket
3 17 S16+RW Ascii16 String 7 (batch ticket print code 2263)
4 6
To print in the batch ticket