72 143 F32+RW Input in UFP (if enabled): pressure proving. external flowmeter 6 8 bar
73 145 F32+RW Input in UFP (if enabled): pressure densitometer 6 2 bar
74 147 F32+RW Input in UFP (if enabled): density densitometer 6 2 kg/m3
75 149 F32+RW Input in UFP (if enabled): density standard 6 2 kg/m3
76 151 F32+RW Input in UFP (if enabled): viscosity dynamic 6 1 cSt or 10-6 m2/s
77 153 F32+RW System time UFP adjustment (see B2230 to enable write) 6 4 -7200…7200 s
78 155 F32+R OVERRIDE: Time to update a parameter (read only) 5 s, max 30 sec
79 157 F32+RW OVERRIDE if set is enabled: temperature body to override 6 1 °C
80 159 F32+RW OVERRIDE if set is enabled: temperature process to override 6 2 °C
81 161 F32+RW OVERRIDE if set is enabled: temperature proving to override 6 8 °C
82 163 F32+RW
OVERRIDE if set is enabled: temperature densitometer to
override
6 2 °C
83 165 F32+RW OVERRIDE if set is enabled: pressure process to override 6 1 2 bar
84 167 F32+RW OVERRIDE if set is enabled: pressure proving to override 6 8 bar
85 169 F32+RW OVERRIDE if set is enabled: pressure densitometer to override 6 2 bar
86 171 F32+RW OVERRIDE if set is enabled: density densitometer to override 6 2 kg/m3
87 173 F32+RW OVERRIDE if set is enabled: density standard to override 6 2 kg/m3
88 175 F32+RW OVERRIDE if set is enabled: viscosity dynamic to override 6 1 cSt or 10-6 m2/s
89 177 F32+RW Batch reference number for internal batch ticket 6 4 [ ]
90 179 F32+RW Krohne use: Calibration volume [ ]
91 181 F32+R Input in UFP (if enabled): BS&W Input 6 3 %
92 183 F32+RW Reserved
93 185 F32+RW Reserved
94 187 F32+RW Reserved
95 189 F32+RW Batch Float Start Value 1 batch ticket print code 750 6 4 To print in the batch ticket
96 191 F32+RW Batch Float Start Value 2 batch ticket print code 751 6 4 To print in the batch ticket
97 193 F32+RW Batch Float Start Value 3 batch ticket print code 752 6 4 To print in the batch ticket
98 195 F32+RW Batch Float Start Value 4 batch ticket print code 753 6 4 To print in the batch ticket
99 197 F32+RW Batch Float Start Value 5 batch ticket print code 754 6 4 To print in the batch ticket
100 199 F32+RW Batch Float Stop Value 1 batch ticket print code 755 6 4 To print in the batch ticket
101 201 F32+RW Batch Float Stop Value 2 batch ticket print code 756 6 4 To print in the batch ticket
102 203 F32+RW Batch Float Stop Value 3 batch ticket print code 757 6 4 To print in the batch ticket
103 205 F32+RW Batch Float Stop Value 4 batch ticket print code 758 6 4 To print in the batch ticket
104 207 F32+RW Batch Float Stop Value 5 batch ticket print code 759 6 4 To print in the batch ticket
105 209 F32+RW Reserved
106 211 F32+RW OVERRIDE if set is enabled: BS&W percentage to override 6 3 %
107 213 F32+RW Set number of values (FIFO) for Gross Flow Running Average. 6 1 2…512
108 215 F32+R Batch stop: Alarm 1-4 channels down 4 1 5 s
109 217 F32+R Batch stop: Alarm all channels down 4 1 5 s
110 219 F32+R Batch stop: Alarm API group mismatch 4 2 5 s
111 221 F32+R Batch stop: Alarm system runtime 4 2 5 s
112 223 F32+R Batch stop: Alarm Profile oor 4 1 5 s
113 225 F32+R Batch stop: Alarm Body Temperature oor 4 1 5 s
114 227 F32+R Batch stop: Alarm Process Temperature oor 4 1 2 s
115 229 F32+R Batch stop: Alarm External Temperature oor 4 8 5 s
116 231 F32+R Batch stop: Alarm Densito Temperature oor 4 2 5 s
117 233 F32+R Batch stop: Alarm Process Pressure oor 4 2 5 s
118 235 F32+R Batch stop: Alarm External Pressure oor 4 8 5 s
119 237 F32+R Batch stop: Alarm Densito Pressure oor 4 2 5 s
120 239 F32+R Batch stop: Alarm Density oor 4 2 5 s
121 241 F32+R Batch stop: Alarm Standard Density oor 4 2 5 s
122 243 F32+R Batch stop: Alarm External Viscosity oor 4 8 5 s
123 245 F32+R Batch stop: Override Body Temperature 4 1 5 s
124 247 F32+R Batch stop: Override Process Temperature 4 2 5 s