Manual

ALTOSONIC V
ModBus Manual 0300 rev07 E 7.30855.35.00 Page 42 of 64
87 173 F32+R Batch 1 average Ctl (15°C to process) 4 2 [ ]
88 175 F32+R Batch 1 average Cpl (0 bar to process) 4 2 [ ]
89 177 F32+R Batch 1 average Ctl (15°C to standard) 4 2 [ ]
90 179 F32+R Batch 1 average Cpl (0 bar to standard. always 1) 4 2 [ ]
91 181 F32+R Batch 1 average Ctl (15°C to densitometer) 4 2 [ ]
92 183 F32+R Batch 1 average Cpl (0 bar to densitometer) 4 2 [ ]
93 185 F32+R Batch 1 average Ctl (15°C to proving external flowmeter) 4 8 2 [ ]
94 187 F32+R Batch 1 average Cpl (0 bar to proving external flowmeter) 4 8 2 [ ]
95 189 F32+R Batch 1 average temperature standard 4 2 °C
96 191 F32+R Batch 1 average density process 4 2 kg/m3
97 193 F32+R Batch 1 average flow proces 4 1 m3/h
98 195 F32+R Batch 1 average density proving external flowmeter 4 8 kg/m3
99 197 F32+R Batch 1 average flow proving external flowmeter 4 8 m3/h
100 199 F32+R Batch 1 average Installed Kfactor proving (external flowmeter) 4 8 puls/liter
101 201 F32+R Batch 1 found new Kfactor proving (external flowmeter) 4 8 puls/liter
102 203 F32+R Batch 1 difference installed vs new found Kfactor (external flow 4 8 %
103 205 F32+R Batch 1 alarm: General flow 1-4 channels down 4 1 5 s
104 207 F32+R Batch 1 alarm: General flow all channels down 4 1 5 s
105 209 F32+R Batch 1 alarm: calculation API group mismatch 4 2 5 s
106 211 F32+R Batch 1 alarm: system runtime alarm occured 4 1 5 s
107 213 F32+R Batch 1 alarm: real time profile out of range when used 4 1 5 s
108 215 F32+R Batch 1 alarm: measurement out of range temperature body 4 1 5 s
109 217 F32+R Batch 1 alarm: measurement out of range temperature process 4 2 5 s
110 219 F32+R Batch 1 alarm: measurement out of range temperature proving 4 8 5 s
111 221 F32+R Batch 1 alarm: measurement out of range temperature densitometer 4 2 5 s
112 223 F32+R Batch 1 alarm: measurement out of range pressure process 4 1 2 s
113 225 F32+R Batch 1 alarm: measurement out of range pressure proving (ext flow) 4 8 5 s
114 227 F32+R Batch 1 alarm: measurement out of range pressure densitometer 4 2 5 s
115 229 F32+R Batch 1 alarm: measurement out of range density densitometer 4 2 5 s
116 231 F32+R Batch 1 alarm: measurement out of range density standard 4 2 5 s
117 233 F32+R Batch 1 alarm: measurement out of range viscosity external 4 1 5 s
118 235 F32+R Batch 1 alarm: OVERRIDE applied temperature body 4 1 5 s
119 237 F32+R Batch 1 alarm: OVERRIDE applied temperature process 4 2 5 s
120 239 F32+R
Batch 1 alarm: OVERRIDE applied temperature proving (ext
flowmeter)
4 8 5 s
121 241 F32+R Batch 1 alarm: OVERRIDE applied temperature densitometer 4 2 5 s
122 243 F32+R Batch 1 alarm: OVERRIDE applied pressure process 4 1 2 s
123 245 F32+R Batch 1 alarm: OVERRIDE applied pressure proving (ext flowmeter) 4 8 5 s
124 247 F32+R Batch 1 alarm: OVERRIDE applied pressure densitometer 4 2 5 s
125 249 F32+R Batch 1 alarm: OVERRIDE applied density densitometer 4 2 5 s
126 251 F32+R Batch 1 alarm: OVERRIDE applied density standard 4 2 5 s
127 253 F32+R Batch 1 alarm: OVERRIDE applied viscosity external 4 1 5 s
128 255 F32+R Batch 2 average temperature body 4 1 °C
129 257 F32+R Batch 2 average temperature process 4 2 °C
130 259 F32+R Batch 2 average temperature proving (external flowmeter) 4 8 2 °C
131 261 F32+R Batch 2 average temperature densitometer 4 2 °C
132 263 F32+R Batch 2 average pressure process 4 1 2 bar
133 265 F32+R Batch 2 average pressure proving (external flowmeter) 4 8 2 bar
134 267 F32+R Batch 2 average pressure densitometer 4 2 bar
135 269 F32+R Batch 2 average density densitometer 4 2 kg/m3
136 271 F32+R Batch 2 average density standard 4 2 kg/m3
137 273 F32+R Batch 2 avarage BS&W in percent 4 3 cSt or 10-6 m2/s
138 275 F32+R Batch 2 average Ctl (15°C to process) 4 2 [ ]
139 277 F32+R Batch 2 average Cpl (0 bar to process) 4 2 [ ]