Manual

ALTOSONIC V
ModBus Manual 0300 rev07 E 7.30855.35.00 Page 41 of 64
34 67 F32+R Krohne use only
35 69 F32+R Krohne use only
36 71 F32+R Krohne use only
37 73 F32+R Krohne use only
38 75 F32+R Remaining hold time on real-profile sampling. By flow deviation 5 1 s
39 77 F32+R Average by stdev: raw UFCdata Flow channel 1 5 1 0 to 1000
40 79 F32+R Average by stdev: raw UFCdata Flow channel 2 5 1 0 to 1000
41 81 F32+R Average by stdev: raw UFCdata Flow channel 3 5 1 0 to 1000
42 83 F32+R Average by stdev: raw UFCdata Flow channel 4 5 1 0 to 1000
43 85 F32+R Average by stdev: raw UFCdata Flow channel 5 5 1 0 to 1000
44 87 F32+R Viscosity external (default not used) 1 cSt or 10-6 m2/s
45 89 F32+R Temperature densitometer 2 °C
46 91 F32+R Pressure densitometer 2 bar
47 93 F32+R Temperature proving (external flowmeter) 8 °C
48 95 F32+R Pressure proving (external flowmeter) 8 bar
49 97 F32+R stdev: raw UFCdata Flow channel 1 5 1 %'
50 99 F32+R stdev: raw UFCdata Flow channel 2 5 1 %'
51 101 F32+R stdev: raw UFCdata Flow channel 3 5 1 %'
52 103 F32+R stdev: raw UFCdata Flow channel 4 5 1 %'
53 105 F32+R stdev: raw UFCdata Flow channel 5 5 1 %'
54 107 F32+R Standard deviation of flow 5 1 %'
55 109 F32+R Max deviation on tau2::tau2/10 for correction path 1 5 1 %'
56 111 F32+R Max deviation on tau2::tau2/10 for correction path 2 5 1 %'
57 113 F32+R Max deviation on tau2::tau2/10 for correction path 3 5 1 %'
58 115 F32+R Max deviation on tau2::tau2/10 for correction path 4 5 1 %'
59 117 F32+R Max deviation on tau2::tau2/10 for correction path 5 5 1 %'
60 119 F32+R Max deviation on tau2::tau2/10 for correction flow 5 1 %'
61 121 F32+R Max deviation on treal::treal/10 for profile measure path 1 5 1 %'
62 123 F32+R Max deviation on treal::treal/10 for profile measure path 2 5 1 %'
63 125 F32+R Max deviation on treal::treal/10 for profile measure path 3 5 1 %'
64 127 F32+R Max deviation on treal::treal/10 for profile measure path 4 5 1 %'
65 129 F32+R Max deviation on treal::treal/10 for profile measure path 5 5 1 %'
66 131 F32+R Max deviation on treal::treal/10 for profile measure 5 1 %'
67 133 F32+R Density densitometer 2 kg/m3
68 135 F32+R Maximum flow rate 7 m3/h
69 137 F32+R Ctl (15°C to process) 2 [ ]
70 139 F32+R Cpl (0 bar to process) 2 [ ]
71 141 F32+R Ctl (15°C to standard) 2 [ ]
72 143 F32+R Cpl (0 bar to standard. always 1) 2 [ ]
73 145 F32+R Ctl (15°C to densitometer) 2 [ ]
74 147 F32+R Cpl (0 bar to densitometer) 2 [ ]
75 149 F32+R Ctl (15°C to proving external flowmeter) 2 [ ]
76 151 F32+R Cpl (0 bar to proving external flowmeter) 2 [ ]
77 153 F32+R Batch 1 average temperature body 4 1 °C
78 155 F32+R Batch 1 average temperature process 4 2 °C
79 157 F32+R Batch 1 average temperature proving (external flowmeter) 4 8 °C
80 159 F32+R Batch 1 average temperature densitometer 4 2 °C
81 161 F32+R Batch 1 average pressure process 4 1 2 bar
82 163 F32+R Batch 1 average pressure proving (external flowmeter) 4 8 bar
83 165 F32+R Batch 1 average pressure densitimeter 4 2 bar
84 167 F32+R Batch 1 average density densitometer 4 2 kg/m3
85 169 F32+R Batch 1 average density standard 4 2 kg/m3
86 171 F32+R Batch 1 avarage BS&W in percent 4 3 %