Manual
ALTOSONIC V
ModBus Manual 0300 rev07 E 7.30855.35.00 Page 40 of 64
94 187 I32+R CRC for UFS files 1 [ ]
95 189 I32+R CRC for UFP files 1 [ ]
96 191 I32+R CRC for DAT files 1 [ ]
97 193 I32+R CRC for (last) Ticket 1 [ ]
98 195 I32+R CRC for Executable (program) 1 [ ]
99 197 I32+R Serial number xxxxxxyyyy, project number x ( 6 or 7 digits ) 1 [ ]
100 199 I32+R Serial number xxxxxxyyyy, part number y (4 digits always) 1 [ ]
8.5 Field 4 (Read only Float Field)
This data is read only and can be accessed with Modbus function 3 and 4 in Modbus slave
mode and with functions 6 and 16 in Modbus master mode.
By default the start addresses are mapped to address 7000 (default value)
start address
NotModiconComp
start address
ModiconComp
Type+Access
Description
Level
Level
Level
Remark
1 1 F32+R Flow process 1 m
3
/hr
2 3 F32+R Sound velocity average 1 m/s
3 5 F32+R Temperature process 2 °C
4 7 F32+R Pressure process 1 2 bar
5 9 F32+R Density process 1 kg/m
3
6 11 F32+R Temperature body 1 °C
7 13 F32+R Flow standard 2 m
3
/hr
8 15 F32+R Flow mass 2 ton/hr
9 17 F32+R raw UFCdata Flow channel 1 5 1 -1250…1250
10 19 F32+R raw UFCdata Flow channel 2 5 1 -1250…1250
11 21 F32+R raw UFCdata Flow channel 3 5 1 -1250…1250
12 23 F32+R raw UFCdata Flow channel 4 5 1 -1250…1250
13 25 F32+R raw UFCdata Flow channel 5 5 1 -1250…1250
14 27 F32+R Sound velocity of path 1 5 1 m/s
15 29 F32+R Sound velocity of path 2 5 1 m/s
16 31 F32+R Sound velocity of path 3 5 1 m/s
17 33 F32+R Sound velocity of path 4 5 1 m/s
18 35 F32+R Sound velocity of path 5 5 1 m/s
19 37 F32+R Remaining hold time on correction. Due to flow deviation 5 1 m/s
20 39 F32+R Reynolds number 5 1 [ ]
21 41 F32+R Swirl % profile diagnostics 5 1 %
22 43 F32+R Viscosity internal 5 1 cSt or 10
-6
m
2
/s
23 45 F32+R A 5 1 [ ]
24 47 F32+R B 5 1 [ ]
25 49 F32+R A_offset 5 1 [ ]
26 51 F32+R B_offset 5 1 [ ]
27 53 F32+R Kr 5 1 [ ]
28 55 F32+R Ks 5 1 [ ]
29 57 F32+R Skewness % profile diagnostics 5 1 %
30 59 F32+R Kbp Pressure Body expansion correction factor 1 [ ]
31 61 F32+R Kb Thermal Body expansion correction factor 1 [ ]
32 63 F32+R Density standard 2 kg/m
3