Manual

ALTOSONIC V
ModBus Manual 0300 rev07 E 7.30855.35.00 Page 39 of 64
41 81 I32+R Resetable totaliser: mass forward (nett.oil) 3 kg
42 83 I32+R Resetable totaliser: mass reverse (nett.oil) 3 kg
43 85 I32+R Non resetable totaliser: process sum (nett.oil) 3 liter
44 87 I32+R Non resetable totaliser: process forward (nett.oil) 3 liter
45 89 I32+R Non resetable totaliser: process reverse (nett.oil) 3 liter
46 91 I32+R Non resetable totaliser: standard sum (nett.oil) 3 liter
47 93 I32+R Non resetable totaliser: standard forward (nett.oil) 3 liter
48 95 I32+R Non resetable totaliser: standard reverse (nett.oil) 3 liter
49 97 I32+R Non resetable totaliser: mass sum (nett.oil) 3 kg
50 99 I32+R Non resetable totaliser: mass forward (nett.oil) 3 kg
51 101 I32+R Non resetable totaliser: mass reverse (nett.oil) 3 kg
52 103 I32+R Batch start: Resetable Totaliser (sum) 4 1 m3, fraction see Int16 reg
53 105 I32+R Batch start: Resetable Totaliser (forward) 4 1 m3, fraction see Int16 reg
54 107 I32+R Batch start: Resetable Totaliser (reverse) 4 1 m3, fraction see Int16 reg
55 109 I32+R Batch start: Resetable Standard Totaliser (sum) 4 2 m3, fraction see Int16 reg
56 111 I32+R Batch start: Resetable Standard Totaliser (forward) 4 2 m3, fraction see Int16 reg
57 113 I32+R Batch start: Resetable Standard Totaliser (reverse) 4 2 m3, fraction see Int16 reg
58 115 I32+R Batch start: Resetable Mass Totaliser (sum) 4 2 ton, fraction see Int16 reg
59 117 I32+R Batch start: Resetable Mass Totaliser (forward) 4 2 ton, fraction see Int16 reg
60 119 I32+R Batch start: Resetable Mass Totaliser (reverse) 4 2 ton, fraction see Int16 reg
61 121 I32+R Batch start: Extern. Resetable Standard Totaliser (sum) 4 8 m3, fraction see Int16 reg
62 123 I32+R Batch start: Extern. Resetable Standard Totaliser (forward) 4 8 m3, fraction see Int16 reg
63 125 I32+R Batch start: Extern. Resetable Standard Totaliser (reverse) 4 8 m3, fraction see Int16 reg
64 127 I32+R Batch start: NonResetable Totaliser (sum) 4 1 m3, fraction see Int16 reg
65 129 I32+R Batch start: NonResetable Totaliser (forward) 4 1 m3, fraction see Int16 reg
66 131 I32+R Batch start: NonResetable Totaliser (reverse) 4 1 m3, fraction see Int16 reg
67 133 I32+R Batch start: NonResetable Standard Totaliser (sum) 4 2 m3, fraction see Int16 reg
68 135 I32+R Batch start: NonResetable Standard Totaliser (forward) 4 2 m3, fraction see Int16 reg
69 137 I32+R Batch start: NonResetable Standard Totaliser (reverse) 4 2 m3, fraction see Int16 reg
70 139 I32+R Batch start: NonResetable Mass Totaliser (sum) 4 2 ton, fraction see Int16 reg
71 141 I32+R Batch start: NonResetable Mass Totaliser (forward) 4 2 ton, fraction see Int16 reg
72 143 I32+R Batch start: NonResetable Mass Totaliser (reverse) 4 2 ton, fraction see Int16 reg
73 145 I32+R Batch stop: Resetable Totaliser (sum) 4 1 m3, fraction see Int16 reg
74 147 I32+R Batch stop: Resetable Totaliser (forward) 4 1 m3, fraction see Int16 reg
75 149 I32+R Batch stop: Resetable Totaliser (reverse) 4 1 m3, fraction see Int16 reg
76 151 I32+R Batch stop: Resetable Standard Totaliser (sum) 4 2 m3, fraction see Int16 reg
77 153 I32+R Batch stop: Resetable Standard Totaliser (forward) 4 2 m3, fraction see Int16 reg
78 155 I32+R Batch stop: Resetable Standard Totaliser (reverse) 4 2 m3, fraction see Int16 reg
79 157 I32+R Batch stop: Resetable Mass Totaliser (sum) 4 2 ton, fraction see Int16 reg
80 159 I32+R Batch stop: Resetable Mass Totaliser (forward) 4 2 ton, fraction see Int16 reg
81 161 I32+R Batch stop: Resetable Mass Totaliser (reverse) 4 2 ton, fraction see Int16 reg
82 163 I32+R Batch stop: Extern. Resetable Standard Totaliser (sum) 4 8 m3, fraction see Int16 reg
83 165 I32+R Batch stop: Extern. Resetable Standard Totaliser (forward) 4 8 m3, fraction see Int16 reg
84 167 I32+R Batch stop: Extern. Resetable Standard Totaliser (reverse) 4 8 m3, fraction see Int16 reg
85 169 I32+R Batch stop: NonResetable Totaliser (sum) 4 1 m3, fraction see Int16 reg
86 171 I32+R Batch stop: NonResetable Totaliser (forward) 4 1 m3, fraction see Int16 reg
87 173 I32+R Batch stop: NonResetable Totaliser (reverse) 4 1 m3, fraction see Int16 reg
88 175 I32+R Batch stop: NonResetable Standard Totaliser (sum) 4 2 m3, fraction see Int16 reg
89 177 I32+R Batch stop: NonResetable Standard Totaliser (forward) 4 2 m3, fraction see Int16 reg
90 179 I32+R Batch stop: NonResetable Standard Totaliser (reverse) 4 2 m3, fraction see Int16 reg
91 181 I32+R Batch stop: NonResetable Mass Totaliser (sum) 4 2 ton, fraction see Int16 reg
92 183 I32+R Batch stop: NonResetable Mass Totaliser (forward) 4 2 ton, fraction see Int16 reg
93 185 I32+R Batch stop: NonResetable Mass Totaliser (reverse) 4 2 ton, fraction see Int16 reg