ALTOSONIC V
ModBus Manual 0300 rev07 E 7.30855.35.00 Page 33 of 64
71 B+RW
EXT: save changed data in float write field (EXT
222..225)
8
6 automatic reset
72 B+RW EXT: restart proving of external flowmeter
8
6 automatic reset
73 B+RW
Batch 1 reset averages For Continuous Pipe Line
Measurement by host , not for the UFP internal CPL
batch mode
4 automatic reset
74 B+RW
Batch 2 reset averages
For Continuous Pipe Line Measurement by
host , not for the UFP internal CPL batch mode
4 6 automatic reset
75 B+RW
Modbus output for all totalisers and batch 1+2 values
on hold for 30 sec. (Internally all totalisers continue)
4
6 automatic reset
76 B+RW
During batch. Guard Digital contact,
CLNT0300.DAT item 20.04 and 20.05,see also
Operating manual 10.4.3
4 6 automatic reset
77..200 Reserved
201 B+RW API enable writing data
2
6 reset after 30 sec
202 B+RW API change in: correction type
2
6 manual reset
203 B+RW API change in: density standard type
2
6 manual reset
204 B+RW API change in: fluid type
2
6 manual reset
205 B+RW API change in: stand. density crude (fluid type 0)
2
6 manual reset
206 B+RW API change in: stand. density gasoline (fluid type 1)
2
6 manual reset
207 B+RW API change in: stand. density trans.area (fluid type 2)
2
6 manual reset
208 B+RW API change in: stand. density jet group (fluid type 3)
2
6 manual reset
209 B+RW API change in: stand. density fuel oil (fluid type 4)
2
6 manual reset
210 B+RW API change in: stand. density free fill (fluid type 5)
2
6 manual reset
211 B+RW API change in: free Fill K0
2
6 manual reset
212 B+RW API change in: free Fill K1
2
6 manual reset
213 B+RW API change in: free Fill K2
2
6 manual reset
214 B+RW API change in: temperature standard
2
6 manual reset
215 B+RW Change in: correction standard
2
6 manual reset
216 B+RW Change in: ASTM-IP stand. density
2
6 manual reset
217 B+RW Change in: LPG stand. density
2
6 manual reset
218 B+RW Change in: LPG equilibrium pressure
2
6 manual reset
219..220 Reserved
221 B+RW EXT enable writing data
8
6 automatic reset
222 B+RW EXT change in: K-factor external flowmeter
8
6 manual reset
223 B+RW
EXT change in: parameters changeable under flowing
conditions or under low flow cuttoff
8
6 manual reset
224 B+RW Change in: MeterFactor (Fwd)
1
6
if enabled in set-
up
225 B+RW Change in: MeterFactor (Rev)
1
6
if enabled in set-
up
226..229 Reserved
230 B+RW SYSTEM TIME deviation enable writing (see float 7577)
4
6
if enabled in set-
up
231 B+RW SOLARTRON1 enable writing data
2
6 automatic reset
232 B+RW SOLARTRON1 change in: calibration data
2
6 automatic reset
233 B+RW SOLARTRON1 save and enable written data 2 6 automatic reset
234 B+RW SOLARTRON2 enable writing data
2
6 automatic reset
235 B+RW SOLARTRON2 change in: calibration data
2
6 automatic reset
236 B+RW SOLARTRON2 save and enable written data
2
6 automatic reset
237 B+RW SARASOTA1 enable writing data
2
6 automatic reset
238 B+RW SARASOTA1 change in: calibration data 2 6 automatic reset
239 B+RW SARASOTA1 save and enable written data
2
6 automatic reset
240 B+RW SARASOTA2 enable writing data
2
6 automatic reset
241 B+RW SARASOTA2 change in: calibration data
2
6 automatic reset
242 B+RW SARASOTA2 save and enable written data
2
6 automatic reset
243 B+RW OVERRIDE: enable writing data
1
2 6
automatic reset
30s
244 B+RW OVERRIDE: change in: OVERRIDE data
1
2 6 automatic reset